dc.description |
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Ambiental, Florianópolis, 2012 |
pt_BR |
dc.description.abstract |
O tanque séptico é uma das tecnologias do saneamento descentralizado mais empregada para o tratamento de esgoto doméstico no Brasil, sendo utilizado por cerca de um quarto da população. Em sua operação é gerado em média um litro de lodo de esgoto por pessoa diariamente, o que remete à produção de um volume considerável deste resíduo em escala nacional. Devido suas características físico-químicas e biológicas, o lodo de tanque séptico necessita de processos de gestão eficientes, a fim de eliminar os seus impactos à saúde pública e ao ambiente, e de valorizar o seu potencial de uso agrícola. Os objetivos deste estudo foram caracterizar o lodo bruto de um tanque séptico, avaliar a eficiência de dois filtros plantados com macrófitas no tratamento de lodo de tanque séptico, denominados F1 e F2, com 4,3 m² de área superficial, 0,75 m de leito filtrante e diferentes espessuras de lodo acumulado, caracterizar o lodo acumulado formado na operação dos filtros e monitorar o seu processo de desaguamento e mineralização. A operação dos filtros foi realizada semanalmente durante os meses de maio a novembro de 2010, com taxa de alimentação de 125 kgST.m-².ano-1, fluxo em batelada e tempo de detenção hidráulica de 6 dias. O lodo séptico bruto e o líquido percolado gerado na operação dos filtros foram coletados e analisados semanalmente. Foram avaliados os parâmetros DQO, pH, alcalinidade, sólidos totais, sólidos totais voláteis, sólidos totais fixos, nitrogênio amoniacal, nitrito e nitrato, e fósforo ortofosfato. Os processos de desaguamento e mineralização do lodo acumulado na superfície de cada filtro foram monitorados durante os meses de outubro de 2010 a outubro de 2011 com a análise dos parâmetros ST e STV. Para a caracterização do lodo acumulado foram analisados os parâmetros pH, matéria orgânica, carbono orgânico total, nitrogênio total, fósforo total, potássio total, cálcio total, magnésio total, e os metais pesados, cobre, cádmio, chumbo, cromo, níquel e zinco. Os filtros apresentaram eficiências superiores a 87% na remoção da matéria orgânica e nutrientes. A espessura da camada de lodo acumulado não apresentou interferência na remoção dos parâmetros DQO, N-NH4+ e P-PO43-, contudo a camada de lodo mais espessa do filtro F1 pode ter influenciado para a melhor remoção dos sólidos totais observada neste filtro. O lodo acumulado dos filtros F1 e F2 apresentaram a maior concentração de ST, 51 e 49%, respectivamente, 83 dias após o último ciclo de alimentação dos filtros. O lodo acumulado nos filtros F1 e F2 apresentou teores de matéria orgânica na faixa de 22,5-39,0%, de nitrogênio total entre 1,1-2,0%, e conteúdos médios de 0,7% de fósforo total e 0,08% de potássio total. As concentrações de metais pesados no lodo acumulado de ambos os filtros estão dentro dos limites permitidos pela legislação nacional para uso agrícola.<br> |
pt_BR |
dc.description.abstract |
Abstract : The septic tank is a decentralized sanitation technology most often employed for the treatment of domestic sewage in Brazil, being used by about a quarter of the population. In its operation is generated on average one liter of sewage sludge per person daily, which leads to the production of a considerable amount of this waste on national scale. Due to physicochemical and biological characteristics, sludge from septic tank needs efficient management processes in order to eliminate their impacts to public health and the environment, and enhance their potential for agricultural reuse. The objectives of this study were to characterize the raw sludge from a septic tank, to evaluate the efficiency of two constructed wetlands in the treatment of septic sludge, called F1 and F2, with 4.3 m² surface area, 0.75 m filter bed and different thicknesses of accumulated sludge, to characterize accumulated sludge formed in the operation of the filters and to monitor the process of dewatering and mineralization. The operation of the filters was carried out weekly during the months of May to November 2010, with feed rate of 125 kgTS.m-².year-1, batch flow and hydraulic retention time of 6 days. The raw septic sludge and leachate generated in the operation of the filters were collected and analyzed weekly. Were evaluated the parameters COD, pH, alkalinity, total solids, total volatile solids, total fixed solids, ammonia, nitrite and nitrate, and orthophosphate. The process of dewatering and mineralization of accumulated sludge on the surface of each filter was monitored during the months of October 2010 to October 2011 with the analysis of the parameters TS and VS. For the characterization of accumulated sludge were analyzed pH, organic matter, total organic carbon, total nitrogen, total phosphorus, total potassium, total calcium, total magnesium, and heavy metals, copper, cadmium, lead, chromium, nickel and zinc. The filters had efficiencies greater than 87% in the removal of organic matter and nutrients. The thickness of the accumulated sludge not showed interference on removal of the parameters COD, NH4+-N and PO43--P, however the thickest layer of accumulated sludge in the filter F1 may have influenced for better removal of total solids found in this filter. The accumulated sludge in the filters F1 and F2 showed the highest concentration of TS, 51 and 49%, respectively, 83 days after the last feeding cycle of the filters. The accumulated sludge in the filters F1 and F2 showed organic matter levels in the range of 22.5-39.0%, total nitrogen between 1.1-2.0%, and average content of 0.7% total phosphorus and 0.08% potassium total. The concentrations of heavy metals in the accumulated sludge of both filters are within the limits allowed by national legislation for agricultural reuse. |
en |
dc.format.extent |
101 p.| il., grafs., tabs. |
pt_BR |
dc.language.iso |
por |
pt_BR |
dc.subject.classification |
Engenharia ambiental |
pt_BR |
dc.subject.classification |
Lodo |
pt_BR |
dc.subject.classification |
Tanques septicos |
pt_BR |
dc.subject.classification |
Macrófita |
pt_BR |
dc.subject.classification |
Filtros e filtração |
pt_BR |
dc.title |
Caracterização de lodo de tanque séptico e tratamento em filtros plantados com macrófitas |
pt_BR |
dc.type |
Dissertação (Mestrado) |
pt_BR |