dc.contributor |
Universidade Federal de Santa Catarina |
pt_BR |
dc.contributor.advisor |
Guglielmo, Luiz Guilherme Antonacci |
pt_BR |
dc.contributor.author |
Floriano, Leandro Teixeira |
pt_BR |
dc.date.accessioned |
2013-06-26T00:47:27Z |
|
dc.date.available |
2013-06-26T00:47:27Z |
|
dc.date.issued |
2012 |
|
dc.date.submitted |
2012 |
pt_BR |
dc.identifier.other |
314355 |
pt_BR |
dc.identifier.uri |
http://repositorio.ufsc.br/xmlui/handle/123456789/101014 |
|
dc.description |
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Desportos, Programa de Pós-Graduação em Educação Física, Florianópolis, 2012 |
pt_BR |
dc.description.abstract |
O principal objetivo deste estudo foi determinar e comparar o consumo máximo de oxigênio obtido em protocolo de campo (T-CAR) e laboratório. Para tal, dez atletas de futsal treinados (27,4 ± 5,8 anos; 78,8 ± 8,5 Kg; 175,8 ± 6,8 cm e 14,1 ± 2,6 %G) realizaram em dias diferentes as seguintes avaliações: 1) teste incremental intermitente de campo (T-CAR) iniciando em 9,0 km.h-1 (15 m) com incrementos de 0,6 km.h-1 a cada estágio (90 segundos), até a exaustão voluntária. Foram identificadas o pico de velocidade (PV), limiar de transição fisiológica (80,4%PV) e FCmax; 2) protocolo incremental de esteira rolante (0,6 km.h-1 a cada 1 minuto) para determinação do PV, VO2max, máxima velocidade aeróbia (MVA), limiar ventilatório (LV), quociente respiratório máximo (Rmax), ventilação respiratória máxima (VEmax), lactato pico ([la]pico) e FCmax; 3) protocolo de tempo limite (Tlim), na qual os atletas foram submetidos a um exercício em carga constante (100%PV do T-CAR). Desse teste foram determinados Tlim (segundos), VO2max, VEmax, Rmax, [la]pico e FCmax. Nesta ultimo protocolo o VO2 foi mensurado simultâneo a execução do teste. O PV, obtido no T-CAR, não foi estatisticamente diferente da MVA, alcançada em laboratório (p=0,213). Todos os atletas alcançaram seus valores máximos de VO2, na execução do Tlim. O VO2max, relativo e absoluto, alcançado durante a execução do Tlim não diferiu do obtido em laboratório (49 ± 4,7 e 51,1 ± 4,7 ml.kg-1.mim-1, respectivamente) (p=0,100). Não foram encontradas diferenças na FCmax (p=0,095) e VEmax (p=0,373) em campo e laboratório. O [la]pico (p<0,05), assim como o Rmax (p=0,095) apresentaram diferença entre os protocolos, com valores significantemente maiores alcançados em campo. Dessa forma concluiu-se que o PV obtido no T-CAR pode ser utilizado como um indicador de potência aeróbia máxima, assim como, durante a execução de um exercício em carga constante (100%PV) permite que atletas de futsal alcancem respostas cardiorrespiratórias máximas antes da exaustão voluntária.<br> |
pt_BR |
dc.description.abstract |
Abstract : The main objective of this study was to determine and compare the maximum oxygen consumption obtained in field test (T-CAR) and laboratory. For this, ten trained soccer indoor players (27.4 ± 5.8 years, 78.8 ± 8.5 kg, 175.8 ± 6.8 cm and 14.1 ± 2.6% G) performed on different days the following assessments: 1) intermittent incremental field test (T-CAR) starting at 9.0 km.h-1 (15 m) with increments of 0.6 km.h-1 at each stage (90 seconds) until voluntary exhaustion. We identified peak velocity (PV), physiological transition threshold (80.4% PV) and HRmax, 2) incremental treadmill protocol (0.6 km.h-1 every 1 minute) for determination of PV, VO2max, maximal aerobic speed (MVA), ventilatory threshold (VT), respiratory quotient maximum (Rmax), maximal respiratory ventilation (VEmax), peak lactate ([la]peak) and HRmax, 3) protocol time limit (Tlim) in which athletes underwent an exercise in constant load (100% of the PV T-CAR). It were determined Tlim (seconds) VO2max, VEmax, Rmax, [la]peak and HRmax. In this latter protocol VO2 was measured simultaneously test execution. The PV obtained in T-CAR, was not statistically different from the MVA, achieved in the laboratory (p = 0.213). All athletes reached their maximum VO2 in during the Tlim. VO2max, relative and absolute, reached during the execution of Tlim not differ from that obtained in the laboratory (49 ± 4.7 and 51.1 ± 4.7 ml.kg-1.mim-1, respectively) (p = 0.100). No differences were found in HRmax (p = 0.095) and VEmax (p = 0.373) in the field and laboratory tests. The [la]peak (p <0.05), as well as the Rmax (p = 0.095) were different between the protocols, with significantly higher values achieved in the field. Thus it was concluded that the PV obtained in T-CAR can be used as an indicator of maximal aerobic power, as well as during the execution of an exercise in constant load (100% BW) allows soccer indoor athletes reach peak cardiorespiratory responses before voluntary exhaustion. |
en |
dc.format.extent |
70 p.| grafs., tabs. |
pt_BR |
dc.language.iso |
por |
pt_BR |
dc.subject.classification |
Educação física |
pt_BR |
dc.subject.classification |
Futebol de salao |
pt_BR |
dc.subject.classification |
Jogadores de futebol |
pt_BR |
dc.subject.classification |
Fisiologia |
pt_BR |
dc.subject.classification |
Aptidao fisica do atleta |
pt_BR |
dc.subject.classification |
Exercicios aerobicos |
pt_BR |
dc.title |
Avaliação aeróbia em jogadores de futsal: determinação e comparação do Vo2max em protocolo de campo (T-CAR) e laboratório |
pt_BR |
dc.type |
Dissertação (Mestrado) |
pt_BR |