Determinação eletroanalítica de compostos fenólicos utilizando um eletrodo de pasta de carbono modificado com poli(vinilpirrolidona)

DSpace Repository

A- A A+

Determinação eletroanalítica de compostos fenólicos utilizando um eletrodo de pasta de carbono modificado com poli(vinilpirrolidona)

Show simple item record

dc.contributor Universidade Federal de Santa Catarina pt_BR
dc.contributor.advisor Spinelli, Almir pt_BR
dc.contributor.author Piovesan, Jamille Valéria pt_BR
dc.date.accessioned 2014-08-06T18:00:53Z
dc.date.available 2014-08-06T18:00:53Z
dc.date.issued 2014 pt_BR
dc.identifier.other 326893 pt_BR
dc.identifier.uri https://repositorio.ufsc.br/xmlui/handle/123456789/123276
dc.description Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências Físicas e Matemáticas, Programa de Pós-Graduação em Química, Florianópolis, 2014. pt_BR
dc.description.abstract pt_BR
dc.description.abstract Abstract : A carbon paste electrode modified with poly (vinylpyrrolidone) polymer was used to study the electrochemical quercetin and kaempferol and the electroanalytical determination of phenol compounds and in pharmaceutical vegetable matrices. About this electrode , cyclic voltammograms of quercetin presented three oxidation peaks located at +0.32 , +0.78 and +1.04 V. The electro-oxidation in the first peak leads to the formation of the corresponding ortho-quinone, which can be reduced in favorable experimental conditions. Under these favorable conditions, the reaction is quasi-reversible, and the process is controlled by diffusion. This behavior has been exploited for the electroanalytical determination of quercetin by square-wave voltammetry. The calibration curve obtained for quercetin was linear in the concentration range from 0.5 to 5.5 mmol L-1 (R2 = 0.998). The limits of detection and quantification were 0.17 ?mol L-1 and 0.52 ?mol L-1, respectively. The sensor was used for the determination of quercetin in pharmaceuticals. The accuracy of the results provided by the sensor was evaluated by comparison with the results obtained by UV-vis technique. The sensor was also applied to study the electrochemical behavior of kaempferol and quantification of phenolic compounds in plant samples. About this electrode, cyclic voltammograms for kaempferol showed only one oxidation peak at +0.58 V and a signal reduction in +0.46 V. Under favorable conditions, the reaction is quasi-reversible, and the process is controlled by diffusion. The calibration curve for the kaempferol showed two linear ranges in concentration ranges of 0.05 to 0.50 ?mol L-1 and 0.50 to 6.0 ?mol L-1 (R2 = 0.980). Using the most sensitive range, the limits of detection and quantification were 45.0 nmol L-1 and 138.0 nmol L-1, respectively. The sensor was applied to the electroanalytical determination of phenolics by square-wave voltammetry compounds in plant samples. The content of total phenolic compounds were expressed in terms of kaempferol (CE)/g of plant in nature mg. The plant that showed a higher content of phenolics was spinach (0.32 mg g-1), followed by the cauliflower (0.29 mg g-1), broccoli (0.21 mg g-1) and, finally, with lower concentrations, chicory (0.08 mg g-1). The accuracy of the results provided by the sensor was evaluated by comparison with the results obtained by Folin-Ciocalteau method. en
dc.format.extent 107 p.| il., grafs., tabs. pt_BR
dc.language.iso por pt_BR
dc.subject.classification Química pt_BR
dc.subject.classification Analise eletroquimica pt_BR
dc.subject.classification Eletrodo de carbono pt_BR
dc.subject.classification Fenois pt_BR
dc.title Determinação eletroanalítica de compostos fenólicos utilizando um eletrodo de pasta de carbono modificado com poli(vinilpirrolidona) pt_BR
dc.type Dissertação (Mestrado) pt_BR


Files in this item

Files Size Format View
326893.pdf 1.598Mb PDF View/Open

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Browse

My Account

Statistics

Compartilhar