Remoção de Cryptosporidium spp. no tratamento de águas por filtração em margem: simulação com colunas de sedimento e microesferas de poliestireno

DSpace Repository

A- A A+

Remoção de Cryptosporidium spp. no tratamento de águas por filtração em margem: simulação com colunas de sedimento e microesferas de poliestireno

Show simple item record

dc.contributor Universidade Federal de Santa Catarina pt_BR
dc.contributor.advisor Sens, Mauricio Luiz pt_BR
dc.contributor.author Jangada, Victor Hugo pt_BR
dc.date.accessioned 2015-02-05T20:12:45Z
dc.date.available 2015-02-05T20:12:45Z
dc.date.issued 2014 pt_BR
dc.identifier.other 327994 pt_BR
dc.identifier.uri https://repositorio.ufsc.br/xmlui/handle/123456789/128654
dc.description Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Ambiental, Florianópolis, 2014. pt_BR
dc.description.abstract Com a crescente preocupação a respeito da poluição hídrica e as possíveis doenças que possam ser causadas através da contaminação com protozoários, surge a filtração em margem como uma das possíveis soluções para o problema, já que pode remover através de filtração os organismos que são resistentes a desinfecção química e algumas vezes podem acabar atingindo as redes de distribuição. Sendo assim, este trabalho objetivou avaliar a eficiência da filtração em margem em colunas de sedimento para remoção de Cryptosporidium spp. através do uso microesferas de poliestireno para simulação deste protozoário. Para consecução desta pesquisa, foi realizado um estudo contendo 5 colunas filtrantes a fim de simular os primeiros metros da filtração em margem, onde foram aplicadas as microesferas simuladoras do protozoário Cryptosporidium spp. Previamente a aplicação das microesferas, procurou-se identificar a quantidade de tempo necessária para que o sistema piloto fosse considerado aclimatado. O controle da qualidade da água produzida pela filtração em margem foi realizado através do monitoramento dos seguintes os parâmetros: carbono orgânico total, coliformes totais, condutividade, cor aparente, cor verdadeira, E. Coli, oxigênio dissolvido, pH, sólidos dissolvidos totais, temperatura e turbidez. A análise das microesferas de poliestireno foi realizada em microscópio de fluorescência. Com base nos resultados obtidos, considera-se aclimatado o sistema piloto após 45 dias de operação, pois nessa altura já é possível alcançar resultados suficientemente bons para se enquadrarem na Portaria nº 2914/2011. Foi também possível concluir que a filtração em margem mostrou-se efetiva na remoção de microesferas de poliestireno a partir de 3 m de leito filtrante. No que diz respeito a turbidez como indicador da presença de Cryptosporidium spp., considera-se que este não corresponde a um indicador confiável, pois houve a presença das microesferas de poliestireno até mesmo quando a turbidez alcançava valores menores que 0,5 uT, como recomenda a legislação brasileira.<br> pt_BR
dc.description.abstract Abstract : With the increasing concern about water pollution and possible diseases that may be caused by contamination with protozoa, rises the bank filtration as a possible solution to the problem, since it can remove by filtration, organisms that are resistant to chemical disinfection and can sometimes end up reaching the distribution networks. Thus, this study aimed to evaluate the efficiency of bank filtration by sediment columns for the removal of Cryptosporidium spp. through the use of microspheres for simulation of this protozoan. To achieve this research, was performed a study containing 5 filter columns to simulate the first few meters of bank filtration, where the microspheres simulating the protozoan Cryptosporidium spp. was applied. Previously the application of microspheres, sought to identify the amount of time required for the pilot system to be considered acclimated. The control of the water quality produced by bank filtration was performed by monitoring the following parameters: total organic carbon, total coliform, conductivity, apparent color, true color, E. Coli, dissolved oxygen, pH, total solids dissolved, temperature and turbidity. The analysis of polystyrene microspheres was performed with a fluorescence microscope. Based on the results obtained, it is considered acclimated the pilot system after 45 days of operation, because then it is possible to achieve results good enough to fit the Brazilian legislation. It was also concluded that the bank filtration proved to be effective in the removal of polystyrene microspheres from 3 m filter bed. Regarding the turbidity as an indication of the presence of Cryptosporidium spp., it is considered that this does not correspond to a reliable indicator because there was the presence of polystyrene microspheres even when the turbidity reached values lower than 0,5 NTU, as recommended in Brazilian legislation. en
dc.format.extent 105 p.| il., grafs., tabs. pt_BR
dc.language.iso por pt_BR
dc.subject.classification Engenharia ambiental pt_BR
dc.subject.classification Água pt_BR
dc.subject.classification Purificação pt_BR
dc.subject.classification Filtração pt_BR
dc.subject.classification Poliestireno pt_BR
dc.subject.classification Cryptosporidium pt_BR
dc.title Remoção de Cryptosporidium spp. no tratamento de águas por filtração em margem: simulação com colunas de sedimento e microesferas de poliestireno pt_BR
dc.type Dissertação (Mestrado) pt_BR


Files in this item

Files Size Format View
327994.pdf 1.719Mb PDF View/Open

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Browse

My Account

Statistics

Compartilhar