dc.contributor |
Universidade Federal de Santa Catarina |
pt_BR |
dc.contributor.advisor |
Sayer, Claudia |
pt_BR |
dc.contributor.author |
Polloni, André Eliezer |
pt_BR |
dc.date.accessioned |
2015-02-05T20:23:55Z |
|
dc.date.available |
2015-02-05T20:23:55Z |
|
dc.date.issued |
2014 |
pt_BR |
dc.identifier.other |
327280 |
pt_BR |
dc.identifier.uri |
https://repositorio.ufsc.br/xmlui/handle/123456789/128836 |
|
dc.description |
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Química. Florianópolis, 2014. |
pt_BR |
dc.description.abstract |
No presente trabalho avaliou-se a síntese de diferentes polímeros como poli(adipato de isosorbila), poli(metracrilato de metila) e poli(uréia-uretano) em banho termostático convencional e em banho de ultrassom. Os polímeros foram sintetizados via diferentes técnicas de polimerização como polimerização em massa, miniemulsão e solução, seguindo diferentes mecanismos de reação: em cadeia, etapas e em etapas catalisada por enzimas. Adicionalmente foi avaliado o efeito de diferentes potências do banho de ultrassom (52,8; 92,5 e 132 watts) na síntese dos polímeros. Na polimerização do isosorbídeo e do adipato de dietila em massa e em miniemulsão verificou-se que o banho de ultrassom não afetou a cinética reacional quando comparada com as reações em banho convencional e na polimerização em solução as massas molares apresentaram um leve aumento para as condições de 85°C com 92,5 W e 85°C e 132 W de potência, respectivamente, utilizando um sistema ciclohexano:benzeno como solventes. O mesmo comportamento foi observado na síntese do poli(metracrilato de metila) em massa e em miniemulsão com o uso do banho de ultrassom, sendo que o uso deste não afetou a velocidade de reação e ocasionou uma ligeira redução nas massas molares do poli(metracrilato de metila) obtido via miniemulsão em banho de ultrassom a 132 W de potência. Os estudos para a obtenção de nanopartículas de poli(uréia-uretano) via polimerização em miniemulsão em banho termostático e em banho de ultrassom revelaram que diferentes temperaturas de reação na faixa entre 60°C e 80°C no banho de ultrassom influenciaram diretamente nas massas molares dos polímeros e no aumento da taxa de reação do monômero, enquanto que a variação da potência máxima do ultrassom na faixa estudada (92,5 a 132 W) alterou a taxa de reação, mas não afetou as massas molares, sendo alcançadas massas molares ponderais médias em torno de 20000 g/mol nas reações realizadas a 70°C em banho de ultrassom.<br> |
pt_BR |
dc.description.abstract |
Abstract: This work presents the synthesis of various polymeric materials such as poly(isosorbide adipate), poly(methyl methacrylate) and poly(urea-urethane) in conventional thermostatic and ultrasound bath. The polymers were synthesized by bulk, solution and miniemulsion polymerizations, following different reaction mechanisms: chain polymerization, step polymerization and enzimatically catalized step polymerization. Aditionally the effect of power of the ultrasound bath (52.8, 92.5 and 132 watts) was evaluated. In the polymerization of the poly (isosorbide adipate) in mass and in solution it was found that the ultrasound bath does not affect the reaction kinetics when compared with conventional bath. In the solution polymerization, the molar mass increased slightly for the conditions of 85°C at 92.5W and 85°C at 132 W power, respectively, using a ciclohexane:benzene system as solvent. The same behavior was observed in the synthesis of poly (methyl methacrylate) in mass and miniemulsion using the ultrasound bath, and the use of the latter does not affect the reaction kinetics, but lead to a slight reduction in the molecular weight of poly(methyl methacrylate) obtained in miniemulsion via ultrasound bath at 132 W of power. Studies for obtaining nanoparticles of poly(urea-urethane) by miniemulsion polymerization with thermostatic bath, and ultrasound bath revealed that different reaction temperatures in the range between 60°C and 80°C in the ultrasound bath directly influence the molar mass of the polymers and increase the reaction rate of the monomer, while the variation of the maximum power of the ultrasound in the studied range (92.5 to 132 W) affected the reaction rate but did not influence the molar mass. The weight awerage molar mass was around 20000 g/mol for reactions conducted at 70°C in the ultrasound bath. |
en |
dc.format.extent |
88 p.| il., tabs., grafs. |
pt_BR |
dc.language.iso |
por |
pt_BR |
dc.subject.classification |
Engenharia quimica |
pt_BR |
dc.subject.classification |
Polimeros |
pt_BR |
dc.subject.classification |
Síntese |
pt_BR |
dc.subject.classification |
Polimerização |
pt_BR |
dc.subject.classification |
Reações quimicas |
pt_BR |
dc.title |
Síntese de materiais poliméricos assistida por ultrassom |
pt_BR |
dc.type |
Dissertação (Mestrado) |
pt_BR |
dc.contributor.advisor-co |
Araújo, Pedro Henrique Hermes de |
pt_BR |