dc.contributor |
Universidade Federal de Santa Catarina |
pt_BR |
dc.contributor.advisor |
Borges, Daniel Lázaro Gallindo |
pt_BR |
dc.contributor.author |
Quadros, Daiane Paula Cunha de |
pt_BR |
dc.date.accessioned |
2015-09-08T04:07:06Z |
|
dc.date.available |
2015-09-08T04:07:06Z |
|
dc.date.issued |
2015 |
pt_BR |
dc.identifier.other |
334077 |
pt_BR |
dc.identifier.uri |
https://repositorio.ufsc.br/xmlui/handle/123456789/134775 |
|
dc.description |
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro de Ciências Físicas e Matemáticas, Programa de Pós-Graduação em Química, Florianópolis, 2015. |
pt_BR |
dc.description.abstract |
Este trabalho abrange duas técnicas distintas para a determinação de elementos-traço com auxílio da geração fotoquímica de vapor: uma utilizando uma lâmpada de ultravioleta (UV) para a geração da radiação UV com detecção por espectrometria de massa com plasma indutivamente acoplado (ICP-MS) e outra utilizando uma interface micro-ondas/ultravioleta (MW/UV) para a geração da radiação UV e acoplamento com cromatografia líquida de alta eficiência (HPLC) e espectrometria de fluorescência atômica (AFS) para fins de especiação de Hg. Para a análise por ICP-MS, foi desenvolvido um reator fotoquímico aplicável à determinação de Co, Ni e Te em bebidas alcoólicas e determinação de Fe, Sc, Hg e V em amostras de água de mar. Espécies voláteis de Co, Ni, Te, Fe, Sc, Hg e V foram geradas a partir da combinação entre as respectivas soluções padrão e uma mistura dos ácidos fórmico e acético após exposição a uma fonte de UV. Os limites de quantificação de 0,5, 0,1 e 0,4 ng mL-1 para Co, Ni e Te, respectivamente, foram obtidos para a análise de bebidas alcoólicas, os quais correspondem a ganhos de 9, 35 e 3 vezes em relação à análise com nebulização pneumática. Para Hg e V, os limites de quantificação foram de 1,5 e 5,0 ng mL-1, respectivamente, ao passo que Fe e Sc não puderam ser quantificados nas amostras de água do mar, embora a detecção tenha sido realizada com sucesso. Em um segundo projeto, a técnica de geração fotoquímica de vapor por meio de uma interface MW/UV foi acoplada à cromatografia líquida de alta eficiência e à espectrometria de fluorescência atômica (HPLC-AFS) para a quantificação de mercúrio inorgânico, metilmercúrio e etilmercúrio. Durante o processo de desenvolvimento da metodologia foram utilizados os ácidos fórmico, acético, malônico e cítrico para estudos, e o emprego de ácido fórmico como fase móvel mostrou-se mais eficiente para a foto-decomposição de compostos organometálicos de mercúrio e para a redução de Hg2+ a Hg0 sob as condições de MW/UV. Diversos parâmetros operacionais foram avaliados, incluindo o tipo de ácido orgânico e sua concentração, potência de MW, composição da fase móvel de HPLC e ação catalítica de nanopartículas de TiO2. Sob as condições otimizadas, os limites de detecção foram de 0,15, 0,15 e 0,35 ng mL-1 para o mercúrio inorgânico, metilmercúrio e etilmercúrio, respectivamente. O método desenvolvido foi aplicado à análise de três materiais de referência certificados, todos de procedência biológica. A interface online da cromatografia líquida com a fluorescência atômica e a geração fotoquímica de vapor para a determinação de mercúrio é simples, contribui para redução do impacto ambiental associado à análise e representa uma alternativa atraente para o sistema de geração química de vapor baseada no uso de tetraidroborato.<br> |
pt_BR |
dc.description.abstract |
Abstract : This work consists of two distinct approaches for the determination of trace elements by spectrometric techniques, following photochemical vapor generation: in the first approach, an ultraviolet lamp (UV) was used for the generation of volatile species prior to determination by inductively coupled plasma mass spectrometry (ICP-MS); the second approach involved a microwave/ultraviolet (MW/UV) interface for the generation of UV radiation and coupling with high performance liquid chromatography (HPLC) and atomic fluorescence spectrometry (AFS) to carry out speciation analysis. Firstly, a photochemical reactor was built and applied to the development of a new and sensitive method for the determination of Co, Ni and Te in alcoholic beverages and for the identification of Fe, Sc, Hg and V in seawater samples. For these applications, photochemical vapor generation was coupled to an ICP-MS instrument. The volatile species of Co, Ni, Te, Fe, Sc, Hg and V were generated from the combination of a mixture of formic and acetic acid after exposure to a UV source. Limits of quantification of 0.5, 0.1 and 0.4 ng mL-1 for Co, Ni and Te, respectively, were obtained for the analysis of alcoholic beverages, which correspond to 9 (Co), 35 (Ni), and 3 (Te) times improvements over those obtained with conventional pneumatic nebulization. The same setup was adopted for the detection of Hg and V, resulting in quantification limits of 1.5 and 5.0 ng mL-1, respectively. Iron and Sc could not be quantified in seawater samples, although both elements could be effectively detected. On a second project, the hyphenation of photochemical vapor generation with HPLC-AFS was described for the quantification of inorganic mercury, methylmercury and ethylmercury in biological tissues. Formic acid, which was chosen as the mobile phase, was used for the photodecomposition of organomercury compounds and for the reduction of Hg2 + to Hg0 vapor under MW/UV irradiation. The influence of several operating parameters on the response and chromatographic separation efficiency of the species were evaluated, including the type of organic acid and its concentration, MW power, composition of the HPLC mobile phase and catalytic action of TiO2 nanoparticles. Under the optimized conditions, the limits of detection were 0.15, 0.15 and 0.35 ng mL- 1 for inorganic mercury, methylmercury and ethylmercury, respectively. The main analytical figures of merit were determined and the method was applied to the analysis of three certified reference materials. The online interfacing of liquid chromatography with photochemical-vapor generation atomic fluorescence spectrometry for mercury determination was proven relatively simple, environmentally friendly and represents an attractive alternative to the use of chemical vapor generation methods that adopt tetrahydroborate as a reagent. |
en |
dc.format.extent |
1 v.| il., grafs., tabs. |
pt_BR |
dc.language.iso |
por |
pt_BR |
dc.subject.classification |
Química |
pt_BR |
dc.subject.classification |
Fotoquimica |
pt_BR |
dc.subject.classification |
Elementos tracos |
pt_BR |
dc.subject.classification |
Mercurio |
pt_BR |
dc.subject.classification |
Especiação (Química) |
pt_BR |
dc.subject.classification |
Bebidas alcoolicas |
pt_BR |
dc.subject.classification |
Análise |
pt_BR |
dc.subject.classification |
Cromatografia a líquido |
pt_BR |
dc.title |
Emprego da geração fotoquímica de vapor para análise de especiação e determinação de elementos-traço por espectrmetria atômica e de massa |
pt_BR |
dc.type |
Tese (Doutorado) |
pt_BR |