Influência da contaminação da dentina radicular sobre a resistência de união de um cimento resinoso autoadesivo

DSpace Repository

A- A A+

Influência da contaminação da dentina radicular sobre a resistência de união de um cimento resinoso autoadesivo

Show simple item record

dc.contributor Universidade Federal de Santa Catarina pt_BR
dc.contributor.advisor Felippe, Wilson Tadeu pt_BR
dc.contributor.author Costa, Débora Delai pt_BR
dc.date.accessioned 2015-10-06T04:08:19Z
dc.date.available 2015-10-06T04:08:19Z
dc.date.issued 2015 pt_BR
dc.identifier.other 334488 pt_BR
dc.identifier.uri https://repositorio.ufsc.br/xmlui/handle/123456789/135401
dc.description Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2015. pt_BR
dc.description.abstract O objetivo desta pesquisa foi determinar a resistência de união (RU) de um cimento resinoso autoadesivo à dentina radicular humana contaminada. Foram selecionados 20 dentes humanos unirradiculados, os quais tiveram suas coroas e terços apicais seccionados com um disco diamantado em baixa velocidade e sob refrigeração constante, resultando em segmentos de aproximadamente 8 mm. Os canais foram alargados com uma broca de preparo para pino número 2 em baixa rotação (Exacto, Angelus, Londrina, PR, Brasil). Em seguida, foram obtidas 6 secções radiculares de aproximadamente 1mm (3 do terço cervical e 3 do terço médio) em uma máquina de cortes de precisão (Isomet 1000, Buehler, Lake Bluff, IL). As secções foram inseridas individualmente em tubos Eppendorf identificados, e imersas, seqüencialmente, em solução de EDTA 17% por 3 min e NaOCl 1% por 3 min, lavadas, secas com gaze, e esterilizadas em autoclave. O grupo controle foi composto por uma secção de cada terço, as quais foram imersas em TSB estéril por 60 dias (n = 40). Para compor o grupo experimental, as demais secções foram imersas em meio TSB + sacarose 0,4% contendo 108 UFC/mL de E. faecalis por 60 dias, e o meio de cultura foi renovado a cada 4 dias (n = 80). Após o período experimental, as amostras foram lavadas com água destilada, secas com gaze e cones de papel absorvente, e o espaço referente ao canal radicular foi preenchido com o cimento resinoso autoadesivo Rely X U200 (3M/ESPE, St. Paul, MN, USA) conforme as recomendações do fabricante. Após 24h foi realizado o teste push out. Os dados foram analisados estatisticamente pelo teste de Mann-Whitney, com um nível de significância de 5%. O grupo experimental apresentou redução significativa na RU quando comparado com o grupo controle nos dois terços avaliados (p<0,05). Na comparação entre terços, no grupo experimental o terço cervical apresentou maior média de RU (p<0,05). Considerando as limitações deste estudo ex vivo, a contaminação bacteriana influenciou negativamente na RU do cimento resinoso autoadesivo à dentina radicular humana.<br> pt_BR
dc.description.abstract Abstract : The aim of this study was to evaluate ex vivo the bond strength (BS) of a self-adhesive resin cement to human root dentin contaminated through the push out test, and evaluate the pathern of failure that occurred after the test. Twenty single-rooted human teeth had their crowns and apical thirds sectioned with a diamond disk at low speed and under constant cooling, to obtain segments of approximately 8 mm. The root canals have been extended with a #2 drill at low rpm (Exacto, Angelus, Londrina, PR, Brazil). Six root sections of 1 mm thickness were obtained (3 from the cervical third and 3 from the middle third) on a precision cutting machine (1000 Isomet, Buehler, Lake Bluff, IL). The sections were inserted in labeled Eppendorf tubes and immersed in 17% EDTA solution for 3 min followed by 1% NaOCl for 3 min, washed, dried with gauze and sterilized. The control group was composed by one section of each third, which were immersed in sterile TSB for 60 days (n = 40). To make the experimental group, the other sections were immersed in TSB medium containing 0.4% sucrose + 108 CFU/mL of E. faecalis for 60 days, and the culture medium was renewed every 4 days (n = 80). After the trial period, the samples were washed with distilled water, dried with gauze and absorbent paper points, and the space related to the root canal was filled with self-adhesive resin cement Rely X U200 (3M / ESPE, St. Paul, MN, USA) according to the manufacturer's instructions. The push out test was performed after 24h. Data were statistically analyzed using the Mann-Whitney test, with a 5% significance level. The experimental group showed a significant reduction in the BS when compared to the control group in both thirds evaluated (p<0.05). When comparing thirds, in the cervical third the experimental group showed higher mean of BS (p<0.05). Considering the limitations of this ex vivo study, bacterial contamination caused damage in self-adhesive resin cement BS to human root dentin. en
dc.format.extent 63 p.| il., tabs. pt_BR
dc.language.iso por pt_BR
dc.subject.classification Odontologia pt_BR
dc.subject.classification Cimentos dentários pt_BR
dc.subject.classification Dentina pt_BR
dc.subject.classification Adesivos dentários pt_BR
dc.title Influência da contaminação da dentina radicular sobre a resistência de união de um cimento resinoso autoadesivo pt_BR
dc.type Dissertação (Mestrado) pt_BR


Files in this item

Files Size Format View
334488.pdf 1.604Mb PDF View/Open

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Browse

My Account

Statistics

Compartilhar