Tratamento de água para abastecimento por meio de filtros lentos de fluxo ascendente com limpeza por retrolavagem e descarga de fundo
Show simple item record
dc.contributor |
Universidade Federal de Santa Catarina |
pt_BR |
dc.contributor.advisor |
Sens, Mauricio Luiz |
pt_BR |
dc.contributor.author |
Souza, Fernando Hymnô de |
pt_BR |
dc.date.accessioned |
2015-10-27T03:07:31Z |
|
dc.date.available |
2015-10-27T03:07:31Z |
|
dc.date.issued |
2015 |
pt_BR |
dc.identifier.other |
335772 |
pt_BR |
dc.identifier.uri |
https://repositorio.ufsc.br/xmlui/handle/123456789/135792 |
|
dc.description |
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Ambiental, Florianópolis, 2015. |
pt_BR |
dc.description.abstract |
Esta dissertação aborda o tratamento de água por meio de filtração lenta ascendente com a retrolavagem e descarga de fundo com entrada de água na interface entre o meio filtrante e a camada suporte como alternativa à limpeza dos filtros. Em outras pesquisas a retrolavagem foi utilizada com sucesso como forma alternativa de limpeza em filtros lentos descendentes e com área superficial reduzida. Tais filtros são considerados uma excelente alternativa ao fornecimento de água potável em comunidades rurais e/ou isoladas. Os objetivos específicos propostos nessa dissertação foram: Avaliar a limpeza por retrolavagem associada às descargas de fundo, a qualidade da água produzida e a eficiência da camada suporte como pré-tratamento. Para a pesquisa foi construído e operado um sistema piloto com dois filtros lentos ascendentes iguais, com a possibilidade do uso dos três sistemas de limpeza citados. A água que abasteceu o sistema era proveniente de um manancial com densidade em torno de 106 cél./mL da cianobactéria Cylindrospermopsis raciborskii que normalmente prejudica a filtração em termos de duração das carreiras. Foi monitorada a qualidade da água bruta e filtrada, assim como as perdas de carga no meio filtrante e camada suporte dos filtros. Paralelamente foi construído um sistema piloto com três colunas de pré-filtração ascendente, preenchidas com o mesmo material da camada suporte dos filtros e que filtravam a mesma água na mesma taxa de filtração (4 m³/m².d). Em termos de qualidade de água os filtros foram eficientes na remoção de turbidez com médias inferiores a 1,0 uT. Houve também remoção em torno de 2,0 Log de células de Cylindrospermopsis raciborskii e carreiras de mais de 70 dias. Contudo, densidades em torno de 104 cél./mL foram encontradas no efluente, o que relacionado aos resultados de COD e absorbância a 254 nm fazem crer que o efluente dos filtros pode apresentar riscos na formação subprodutos da cloração. Nesses processos de remoção constatou-se que a camada suporte foi influente. Por fim, a associação entre descarga com entrada de água na interface e a retrolavagem demonstrou-se como a melhor alternativa para a limpeza dos filtros lentos ascendentes usados nesse estudo.<br> |
pt_BR |
dc.description.abstract |
Abstract : This work aimed to study alternative filter cleaning to upflow slow sand filters (backwash, bottom discharge and bottom discharge with water entering in the interface between support and filter media). Slow sand filters are considered an excellent alternative for the supply of drinking water in rural areas and/or isolated communities. In some research backwash was successful used as an alternative to the cleaning of slow sand filters with reduced surface area. Such filters have an easier application in small communities or as a home-scale system. The specific objectives proposed were: Assess the backwash associated with bottom discharge for the filter cleaning; evaluate the quality of produced water. It was built two pilot scale upflow slow sand filters that could be cleaned with each cleaning system separately or associated. The water used on the system was from the lake named ?Lagoa do Peri? in Florianópolis, Bazil. This water is known for its cyanobacteria high density (106 cells/mL of Cylindrospermopsis racibosrkii). The headloss on the filter bed and support bed were monitored, as well as the water quality of the rough and filtered water. It was also built three columns of rough filtration systems. These columns were filled with similar gravel that was used on the filter, each one representing each layer of supporting bed. They also operate in the same flow rate as the filters (4 m³/m².day). The upflow slow sand filters were efficient removing turbidity, with average results were below 1.0 NTU, maximum value permitted by the Brazilian law. Water with a 0,9x105 cells/mL density was used with an average of 2.0 log of cells removed. It is supposed that the support bed had an influence on that removal. Nevertheless densities of 104 cells/mL have still being found and though and that may still be a problem to the water treatment. The major advantage of the upflow slow sand filter was the high removal of Cylindrospermopsis raciborskii without filter's running time injuring with filters operating longer than 70 days without the use of rough filters. Although another process of treatment must be used as complement for a higher water quality results. |
en |
dc.format.extent |
118 p.| il., grafs., tabs. |
pt_BR |
dc.language.iso |
por |
pt_BR |
dc.subject.classification |
Engenharia ambiental |
pt_BR |
dc.subject.classification |
Água |
pt_BR |
dc.subject.classification |
Purificação |
pt_BR |
dc.subject.classification |
Filtração |
pt_BR |
dc.title |
Tratamento de água para abastecimento por meio de filtros lentos de fluxo ascendente com limpeza por retrolavagem e descarga de fundo |
pt_BR |
dc.type |
Dissertação (Mestrado) |
pt_BR |
Files in this item
This item appears in the following Collection(s)
Show simple item record
Search DSpace
Browse
-
All of DSpace
-
This Collection
My Account
Statistics
Compartilhar