Performance acústica de uma igreja protestante de médias dimensões

DSpace Repository

A- A A+

Performance acústica de uma igreja protestante de médias dimensões

Show simple item record

dc.contributor Universidade Federal de Santa Catarina pt_BR
dc.contributor.advisor Vergara, Erasmo Felipe
dc.contributor.author Knochenhauer de Souza, Ingrid
dc.date.accessioned 2016-07-19T01:03:39Z
dc.date.available 2016-07-19T01:03:39Z
dc.date.issued 2016-07-01
dc.identifier.uri https://repositorio.ufsc.br/xmlui/handle/123456789/164590
dc.description TCC (graduação) - Universidade Federal de Santa Catarina. Centro Tecnológico. Engenharia Civil. pt_BR
dc.description.abstract Este Trabalho de Conclusão de Curso (TCC) faz o estudo de caso da performance acústica de uma igreja protestante de médias dimensões no centro comercial da cidade de Florianópolis, SC, Brasil, através de simulação computacional com o software comercial Odeon. A resposta impulsiva experimental da igreja foi obtida a partir da excitação sonora no palco e da medição de pressão sonora em diferentes posições para a determinação do Tempo de Reverberação (TR). Este parâmetro acústico da igreja, obtido experimentalmente, foi utilizado para calibrar o modelo virtual do templo com auxílio do programa computacional Odeon. Considerando que o templo estivesse ocupado em 70% da sua capacidade e utilizando a simulação computacional, o desempenho acústico da igreja foi analisado e classificado em termos de parâmetros como Tempo de Reverberação (TR), Tempo de Decaimento Inicial (EDT), Clareza (C80), Definição (D50) e Índice de Transmissibilidade da Fala (STI). O templo sem ocupação de pessoas teve um TR médio medido e simulado de 1,5 segundos, enquanto quando ocupado com 70% da capacidade de pessoas, o TR foi de 1,3 segundos. Através do Odeon, a média de cálculo de outros parâmetros foram: 1,2 segundos de EDT, 2,2 dB de C80 e 0,57 de STI. A reverberação do templo foi considerada boa de acordo suas médias proporções e sua denominação de igreja protestante, pois estava dentro dos valores esperados. No entanto, a sensação foi de menor reverberação do que realmente tinha, pois o parâmetro EDT apresentou valores menores que o TR. A clareza da música foi aceitável de acordo com os valores de C80, mas a inteligibilidade da palavra falada representada por parâmetros de D50 e STI teve valores correspondendo a qualidade de discurso razoável. pt_BR
dc.description.abstract This Conclusion Work Course studies the acoustic performance of a protestant church of medium proportions. This case study was located in the commercial center of the city of Florianópolis, SC, Brazil, and was evaluated through numerical simulation using the commercial software Odeon. The impulse response was obtained through sound excitement at the stage and sound pressure measurements in different audience positions. These measurement results determined the acoustical parameter Reverberation Time (RT). Having the church acoustical parameter experimentally, this RT was used to calibrate the temple virtual model supported by the software Odeon. Considering an occupancy capacity of 70% and using computational simulation, the church acoustic performance was analyzed and classified evaluating parameters as RT, Early Decay Time (EDT), Clarity Index (C80), Definition (D50) and Speech Intelligibility Index (STI). The unoccupied temple had an average measured and simulated RT of 1.5 seconds, while the RT was 1.3 seconds when simulated with 70% of occupancy. Through Odeon, the average of other calculated parameters was: 1.2 seconds for EDT, 2.2 dB for C80 and 0.57 for STI. The church reverberation was considered good as it showed expected values considering its medium proportions and its nomination as a protestant church. However, the subjective judgment of reverberation was lesser than the reverberation time because EDT parameter presented lower values than RT. Music clarity was acceptable according to C80 results, but spoken word intelligibility represented by D50 and STI parameters showed reasonable speech quality. pt_BR
dc.format.extent xx f. pt_BR
dc.language.iso pt_BR pt_BR
dc.publisher Florianópolis, SC pt_BR
dc.subject Acústica arquitetônica pt_BR
dc.subject Acústica de igrejas pt_BR
dc.subject Simulação Acústica pt_BR
dc.title Performance acústica de uma igreja protestante de médias dimensões pt_BR
dc.type TCCgrad pt_BR