dc.contributor |
Universidade Federal de Santa Catarina |
pt_BR |
dc.contributor.advisor |
Welz, Bernhard |
pt_BR |
dc.contributor.author |
Silva, Mauana Schneider da |
pt_BR |
dc.date.accessioned |
2016-09-20T04:51:51Z |
|
dc.date.available |
2016-09-20T04:51:51Z |
|
dc.date.issued |
2016 |
pt_BR |
dc.identifier.other |
340438 |
pt_BR |
dc.identifier.uri |
https://repositorio.ufsc.br/xmlui/handle/123456789/168087 |
|
dc.description |
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências Físicas e Matemáticas, Programa de Pós-Graduação em Química, 2016 |
pt_BR |
dc.description.abstract |
O presente trabalho trata sobre um método simples para a determinação de cádmio e cromo em amostras de óleo de peixe por espectrometria de absorção atômica de alta resolução e fonte continua em forno de grafite. As amostras foram preparadas pela diluição em 1-propanol. Foram utilizados tubos de grafite recobertos de platina e adição de paládio como modificador químico para a determinação de cádmio enquanto para a determinação de cromo não foi utilizado modificador químico permanente ou em solução. A exatidão do método foi avaliada pela comparação entre os resultados obtidos por digestão assistida em micro-ondas, apresentando resultados concordantes com este método alternativo de preparo de amostra. Além de amostras de óleo de peixe, foram quantificadas as concentrações de cádmio e cromo em outras matrizes lipídicas como manteiga de leite e manteiga de cacau. Para cádmio, os limites de detecção e quantificação foram de 0,5 pg e 1,5 pg, respectivamente, a faixa de trabalho foi de 1,5 a 330 pg de cádmio com um coeficiente linear de 0,998. Para cromo, os limites de detecção e quantificação para o método proposto foram de 7 pg e 23 pg, respectivamente; a faixa linear foi de 23 a 1080 pg de cromo, com um coeficiente linear de 0,999.<br> |
pt_BR |
dc.description.abstract |
Abstract: This work presents a simple method to determine cadmium and chromium in fish oil samples in graphite furnace by high-resolution continuum source atomic absorption spectrometry. The samples were prepared by dilution with 1-propanol. For cadmium determination a platinum coated graphite tube and palladium as chemical modifier were used. For chromium determination, no chemical permanent modifier or in solution was employed. The method was evaluated by the comparison with microwave-assisted digested samples, showing a good agreement with this alternative sample preparation. In addition, the concentrations of cadmium and chromium in butter and cocoa butter were measured. For cadmium, the limits of detection and quantification for the developed method were 0.5 pg and 1.5 pg respectively, the working range was 1.5 to 330 pg cadmium with a linear coefficient of 0.998. For chromium, the limits of detection and quantification for the developed method were 7 pg and 23 pg respectively, the working range was 23 to 1080 pg chromium with a linear coefficient of 0.999. |
en |
dc.format.extent |
62 p.| il., grafs., tabs. |
pt_BR |
dc.language.iso |
por |
pt_BR |
dc.subject.classification |
Química |
pt_BR |
dc.subject.classification |
Química analítica |
pt_BR |
dc.subject.classification |
Cádmio |
pt_BR |
dc.subject.classification |
Cromo |
pt_BR |
dc.subject.classification |
Determinação mineralógica |
pt_BR |
dc.title |
Determinação de cádmio e cromo em amostras lipídicas por espectrometria de obsorção atômica de alta resolução com fonte contínua e atomização em forno de grafite |
pt_BR |
dc.type |
Dissertação (Mestrado) |
pt_BR |