Determinação de enxofre em óleo cru utilizando espectrometria de absorção molecular de alta resolução com fonte contínua via molécula SnS em forno de grafite

DSpace Repository

A- A A+

Determinação de enxofre em óleo cru utilizando espectrometria de absorção molecular de alta resolução com fonte contínua via molécula SnS em forno de grafite

Show simple item record

dc.contributor Universidade Federal de Santa Catarina pt_BR
dc.contributor.advisor Welz, Bernhard pt_BR
dc.contributor.author Cadorim, Heloisa Rosangela pt_BR
dc.date.accessioned 2016-09-20T04:53:08Z
dc.date.available 2016-09-20T04:53:08Z
dc.date.issued 2016 pt_BR
dc.identifier.other 339909 pt_BR
dc.identifier.uri https://repositorio.ufsc.br/xmlui/handle/123456789/168101
dc.description Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências Físicas e Matemáticas, Programa de Pós-Graduação em Química, Florianópolis, 2016 pt_BR
dc.description.abstract Um método analítico foi desenvolvido para a determinação de enxofre como molécula de monossulfeto de estanho (SnS) em óleo cru usando espectrometria de absorção molecular de alta resolução com fonte contínua em forno de grafite (HR-CS GF MAS). A absorvância molecular da molécula SnS foi medida usando o comprimento de onda em 271,624 nm e as amostras de óleo cru foram preparadas como microemulsões devido a sua alta viscosidade. Vários modificadores químicos (Ir, Pd, Ru e Zr) foram avaliados e Pd foi escolhido por apresentar o melhor desempenho. O programa de temperatura foi otimizado por comparação entre as curvas de pirólise e vaporização obtidas para o padrão aquoso de S e uma microemulsão de material de referência certificado (CRM) de óleo cru. As temperaturas ótimas de pirólise e vaporização foram 600 e 2000 °C, respectivamente. O limite de detecção e a massa característica encontrados para o método desenvolvido foram 5,8 e 13,3 ng S. A exatidão e a precisão do método foram avaliadas usando dois CRM de óleo cru (NIST SRM 2721 e NIST SRM 2722) e mostraram boa concordância entre os valores encontrados e certificados.<br> pt_BR
dc.description.abstract Abstract: An analytical method for the determination of sulfur, as the tin mono-sulfide (SnS) molecule, in crude oil has been developed using high-resolution continuum source graphite furnace molecular absorption spectrometry (HR-CS GF MAS). The molecular absorbance of the SnS has been measured using the wavelength at 271.624 nm and the crude oil samples were prepared as micro-emulsions due to their high viscosity. Several chemical modifiers (Ir, Pd, Ru, Zr) were tested and palladium was chosen, because it exhibited the best performance. The heating program was optimized by comparing the pyrolysis and vaporization curves obtained for an aqueous sulfur standard and a micro-emulsion of a certified reference material. The optimum pyrolysis and vaporization temperatures were found to be 600 and 2000 ºC, respectively. The limit of detection (LOD) and the characteristic mass (mo) using micro-emulsion analysis of crude oil samples were 5.8 and 13.3 ng S. Accuracy and precision of the method has been evaluated using certified crude oil reference materials (NIST SRM 2721 and NIST SRM 2722), showing good agreement with the informed or certified values. en
dc.format.extent 60 p.| il., grafs., tabs. pt_BR
dc.language.iso por pt_BR
dc.subject.classification Química pt_BR
dc.subject.classification Moléculas pt_BR
dc.subject.classification Absorção e adsorção pt_BR
dc.subject.classification Enxofre pt_BR
dc.subject.classification Petróleo pt_BR
dc.title Determinação de enxofre em óleo cru utilizando espectrometria de absorção molecular de alta resolução com fonte contínua via molécula SnS em forno de grafite pt_BR
dc.type Dissertação (Mestrado) pt_BR


Files in this item

Files Size Format View
339909.pdf 936.8Kb PDF View/Open

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Browse

My Account

Statistics

Compartilhar