dc.contributor |
Universidade Federal de Santa Catarina |
pt_BR |
dc.contributor.advisor |
Venturieri, Giorgini Augusto |
pt_BR |
dc.contributor.author |
Jesus, Felipe Thiago de |
pt_BR |
dc.date.accessioned |
2017-09-26T04:17:29Z |
|
dc.date.available |
2017-09-26T04:17:29Z |
|
dc.date.issued |
2017 |
pt_BR |
dc.identifier.other |
349738 |
pt_BR |
dc.identifier.uri |
https://repositorio.ufsc.br/xmlui/handle/123456789/179779 |
|
dc.description |
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências Agrárias, Programa de Pós-Graduação em Agroecossistemas, Florianópolis, 2017. |
pt_BR |
dc.description.abstract |
O declínio de polinizadores em todo o mundo demanda atenção e a necessidade de se aprofundar os conhecimentos sobre estes insetos. O Brasil, possui aproximadamente 300, das 400 espécies existentes de abelhas-sem-ferrão que é o grupo mais eficiente de polinizadores da flora brasileira, mas, apesar desta singularidade carece de incentivos para pesquisas para o manejo e preservação destes insetos. Neste estudo foi desenvolvido um sistema de aquecimento, via resistência elétrica comandada por termostato digital adaptado a caixas de criação racional com a intenção de, pelo calor, incentivar a multiplicação de ninhos voltados para polinização. No interior das caixas foram implantados sensores de temperatura e umidade, conectados a um microcontrolador, que enviava os dados, via wi-fi, para um servidor em nuvem cujos dados poderiam ser acessados por qualquer aparelho com conexão online. O experimento foi montado no Centro de Ciências Agrárias da UFSC em Florianópolis-SC, ao lado de uma mata em estágio avançado de regeneração. Os dados foram coletados em seis caixas, cada uma contendo um ninho de Plebeia droryana, os quais foram submetidos a dois tratamentos: com temperatura controlada para ficar próxima a 30ºC (sistema aquecido), e com as condições térmicas naturais (sistema controle). Foi desenvolvida uma plataforma, para acesso livre dos dados. Os componentes eletrônicos usados foram todos de baixo custo e acessível no mercado mundial. No sistema controle a umidade relativa foi superior à observada no sistema aquecido e a temperatura ambiente esteve correlacionada à temperatura interna dos ninhos. A umidade do sistema aquecido ficou sempre abaixo da umidade do ambiente externo. No sistema controle, a temperatura interna e externa variou na casa de 2ºC, ou seja, comparável ao ambiente natural de nidificação dentro de fendas ou árvores em ambiente natural. O volume dos ninhos decresceu no sistema aquecido. Este estudo ressalta a importância da umidade relativa de ar no bem-estar desta espécie. Os resultados obtidos sugerem que o sistema de aquecimento deve ser aprimorado para evitar baixar a umidade relativa do ar. Além do baixo custo, a disponibilização do software permitirá melhorias no sistema que poderão proporcionar novos estudos e avanço na meliponicultura.<br> |
pt_BR |
dc.description.abstract |
Abstract : The decline of pollinators around the world deserves attention and deeper knowledge about these insects. In Brazil, there are approximately 300 of the 400 existing species of stingless bees, which is the most efficient group of pollinators in Brazilian flora, but despite this uniqueness, it lacks incentives for research on the management and preservation of these insects. In this study, a heating system was developed, controlled by a digital thermostat, adapted to vertical wooden hive boxes with the intention of encouraging a multiplication of nests to be used in pollination. Inside the boxes were installed temperature and humidity sensors, connected to a microcontroller, which sent the data, via wi-fi, to a cloud server whose data could be accessed by any device with an online connection. The experiment was set up at the Center of Agricultural Sciences of the UFSC in Florianópolis-SC, next to a forest in an advanced stage of regeneration. The data were collected in six boxes, each with a nest of Plebeia droryana, which were submitted to two treatments: temperature controlled to be close to 30ºC (heated system) and natural thermal conditions (control system). A platform was developed for free access to data. The electronic systems were subjected to all aspects of the low cost and accessible in the world market. In the control system the relative humidity was higher than that observed in the heated system and the ambient temperature was correlated to the internal temperature of the nests. The humidity of the heated system was always below the humidity of the external environment. In the control system, the internal and external temperature varied in 2ºC approximately, that is, comparable to the natural nesting environment inside fends of trees in natural environment. The volume of the nests decreased in the heated system. This study highlights the importance of relative air humidity in the well-being of this species. The results suggest that the heating system should be improved to avoid lowering the relative humidity of the air. In addition to the low cost, the availability of the software will allow improvements in the system that may provide new studies and advances in meliponiculture. |
en |
dc.format.extent |
1 v.| il., gráfs., tabs. |
pt_BR |
dc.language.iso |
por |
pt_BR |
dc.subject.classification |
Agroecossistemas |
pt_BR |
dc.subject.classification |
Abelha sem ferrão |
pt_BR |
dc.subject.classification |
Criação |
pt_BR |
dc.title |
Sistema de calefação para ninhos de abelhas-sem-ferrão com controle e leitura de temperatura interna por sistema remoto |
pt_BR |
dc.type |
Dissertação (Mestrado) |
pt_BR |