Controle Ativo de Ruído em Refrigeradores Domésticos

DSpace Repository

A- A A+

Controle Ativo de Ruído em Refrigeradores Domésticos

Show simple item record

dc.contributor Universidade Federal de Santa Catarina pt_BR
dc.contributor.advisor Pagano, Daniel Juan
dc.contributor.author Maran, Amanda Letícia
dc.date.accessioned 2019-07-16T17:13:27Z
dc.date.available 2019-07-16T17:13:27Z
dc.date.issued 2018
dc.identifier.uri https://repositorio.ufsc.br/handle/123456789/197714
dc.description TCC(graduação) - Universidade Federal de Santa Catarina. Centro Tecnológico. Engenharia de Controle e Automação. pt_BR
dc.description.abstract Este trabalho desenvolve um controle ativo de ruído para refrigeradores domésticos, mais especificamente daquele de compressores herméticos, usando o conceito de interferência destrutiva. O compressor foi modelado como uma fonte dipolo e o controle aplicado foi do tipo feedfoward, com um filtro adaptativo baseado no algoritmo de mínimos quadrados (Least Mean Squares). O algoritmo foi validado com o auxílio do Matlab, e sua performance também foi avaliada para casos com adição arbitrária de diferentes níveis de incerteza. Depois, o algoritmo foi traduzido para a linguagem C, para ser utilizado com o DSP. Uma bancada de testes foi montada, composta por uma caixa com isolamento acústico, um microfone de eletreto, uma placa TMS320F28379D da Texas Instruments, e dois alto falantes, um para a excitação (áudio do compressor) e, outro para o controle. Então, o sistema de controle ativo foi testado em casos com uma única frequência de 250 Hz, 120 Hz e ruído rosa. Finalmente, o mesmo sistema foi testado para o ruído de um compressor típico. pt_BR
dc.description.abstract This work develops a noise active control for domestic refrigerators, more specifically of hermetic compressor noise, by using the concept of destructive interference. The compressor was modeled as a dipole source and a feedforward control technique was applied, with an adaptative filter based on the least mean squares algorithm. The algorithm was validated with aid of Matlab, and its performance was also assessed for cases with an arbitrary addition of different levels of uncertainty. After, the algorithm was translated to the C language, to be used within the DSP. A test bench was assembled in an acoustic isolated box, an electret microphone, a TMS320F28379D board from Texas Instruments, and two loudspeakers, one for the excitation (audio from the compressor) and other for control. Then, the active control system was tested in cases with a single frequency of 250 Hz, 120 Hz and pink noise Finally, the same system was tested for a typical compressor noise. pt_BR
dc.language.iso pt_BR pt_BR
dc.publisher Florianópolis, SC. pt_BR
dc.rights Open Access
dc.subject controle ativo, ruído, LMS, compressores, refrigeradores pt_BR
dc.subject active control, noise, LMS, compressors, refrigerators pt_BR
dc.title Controle Ativo de Ruído em Refrigeradores Domésticos pt_BR
dc.type TCCgrad pt_BR


Files in this item

Files Size Format View
PFC - Amanda Letícia Maran - 2018_1.pdf 4.197Mb PDF View/Open

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Browse

My Account

Statistics

Compartilhar