Filtros Passivos Aplicados a Inversores Monofásicos Conectados à Rede Elétrica
Show simple item record
dc.contributor |
Universidade Federal de Santa Catarina |
pt_BR |
dc.contributor.advisor |
Coelho, Roberto Francisco |
|
dc.contributor.author |
Behr, Eduardo Eller |
|
dc.date.accessioned |
2019-07-22T13:05:00Z |
|
dc.date.available |
2019-07-22T13:05:00Z |
|
dc.date.issued |
2019-07-18 |
|
dc.identifier.uri |
https://repositorio.ufsc.br/handle/123456789/197977 |
|
dc.description |
TCC (graduação) - Universidade Federal de Santa Catarina. Centro Tecnológico. Engenharia Elétrica. |
pt_BR |
dc.description.abstract |
Este trabalho apresenta uma topologia de microinversor fotovoltaico
de dois estágios cuja parte inversora é derivada do conversor Dual Buck
para permitir analisar e comparar diferentes topologias de filtros passivos
de interface entre o inversor e a rede elétrica. As configurações L,
LCL, LCL+R, LCL+RC são discutidas e comparadas e, em seguida,
se justifica a utilização do LCL+RC devido ao bom desempenho de
filtragem, baixo custo, baixa amplitude de ressonância e baixas perdas.
Uma metodologia de projeto para o LCL+RC é proposta e comparada
com outras duas já existentes na literatura. São propostas também
duas análises paramétricas do comportamento dinâmico dos filtros baseados
nas funções de transferências por meio de diagramas de Bode
e mapeamento de polos e zeros no plano complexo. A metodologia
de projeto dos componentes magnéticos é deduzida e aplicada nos três
métodos discutidos. Os métodos são então comparados por meio de
simulações e validados pelos resultados experimentais. |
pt_BR |
dc.description.abstract |
This work presents a two stage photovoltaic micro-inverter topology
in which the inverter stage derives from a Dual Buck converter in order
to allow further analysis and comparison among multiple passive filter
topologies used to interface the inverter and the electrical grid. The L,
LCL, LCL+R and LCL+RC topologies are discussed and compared,
followed by the reasoning justifying the use of the LCL+RC due to its
adequate filtering performance, low cost, low resonance amplitude, and
low losses. A methodology for designing the LCL+RC filter is proposed
and compared among other two already described in the literature.
Two filter’s dynamic behavior parametric analysis methods are also
proposed, which are based on the filter’s transfer functions and make
use of Bode diagram and pole-zero mapping on the complex plane. The
magnetics components design methodology is derived and aplied to all
three methods discussed. The methods are then compared by means
of simulations and validated by experimental results. |
pt_BR |
dc.format.extent |
106 |
pt_BR |
dc.language.iso |
por |
pt_BR |
dc.publisher |
Florianópolis, SC |
pt_BR |
dc.rights |
Open Access |
|
dc.subject |
Energia fotovoltaica |
pt_BR |
dc.subject |
Energia renovável |
pt_BR |
dc.subject |
Eletrônica de potência |
pt_BR |
dc.subject |
Filtro LCL |
pt_BR |
dc.subject |
Inversor |
pt_BR |
dc.subject |
Processamento de energia |
pt_BR |
dc.title |
Filtros Passivos Aplicados a Inversores Monofásicos Conectados à Rede Elétrica |
pt_BR |
dc.type |
TCCgrad |
pt_BR |
dc.contributor.advisor-co |
Gruner, Víctor Ferreira |
|