dc.description.abstract |
Este trabalho descreve o desenvolvimento de uma bancada experimental automática com
o objetivo de determinar o perfil de amaciamento em compressores herméticos alternativos
com condições de pressão de sucção e de descarga do compressor controladas. Observações
empíricas da indústria sugerem que em tais dispositivos o fenômeno se apresenta nas
primeiras horas de operação do equipamento, e que enquanto o compressor não estiver
totalmente amaciado os resultados de testes realizados podem não corresponder à natureza
da operação normal do dispositivo. Como o fenômeno não pode ser diretamente medido,
dado que o compressor ́e hermético, foram escolhidas grandezas para medi ̧cão indireta
baseadas em informações gerais estabelecidas sobre o amaciamento. A bancada foi implementada e sua opera ̧c ̃ao foi validada por meio de ensaios em compressores j ́a amaciados, a
partir dos quais foram propostas e realizadas altera ̧c ̃oes na localiza ̧c ̃ao de transdutores e na forma de aquisição dos dados. Foram realizados dois ensaios longos (aproximadamente
26,5 horas e 50 horas) com compressores não amaciados. Os dados obtidos nos ensaios
foram analisados e sugerem a existência de padrões no comportamento de compressores
em tais condições, requerendo ainda análises comparativas com amostras amaciadas para
determinar quais desses padrões melhor representam o processo de amaciamento. |
pt_BR |
dc.description.abstract |
This study describes the development of an automatic test rig for determining the run-
in profile on reciprocating hermetic compressors with controlled suction and discharge
pressure conditions. Empirical observations from industry suggest that in such devices the
phenomenon takes place in the first hours of operation of the equipment, and that the
results of tests executed while the compressor is not totally run in may not correspond to
the its normal operation conditions. As this phenomenon cannot be directly measured,
since the compressor is hermetic, some variables have been chosen to seek correlations
between their behavior during the run in process and the effective level of run in. The
test rig was implemented and its operation was validated through tests using already run
in compressors, from which changes in transducer location and in data aquisition were
proposed and implemented. Two long tests (approximately 24 hours and 50 hours) and
were run using compressors which were not yet run in. The test data were then analised
and they suggest the existence of patterns in the compressor behaviour in such conditions.
However, it is still necessary to perform comparative analysis with already run in samples
to determine which of these patterns better represent the run-in proccess. |
pt_BR |
dc.language.iso |
pt_BR |
pt_BR |
dc.publisher |
Florianópolis, SC. |
pt_BR |
dc.rights |
Open Access |
|
dc.subject |
amaciamento, compressores herméticos alternativos, tribologia. |
pt_BR |
dc.subject |
Run-in, hermetic reciprocating compressors, tribology. |
pt_BR |
dc.title |
Projeto e implementação de uma bancada experimental para determinação do perfil de amaciamento em compressores herméticos alternativos |
pt_BR |
dc.type |
TCCgrad |
pt_BR |
Files in this item
This item appears in the following Collection(s)
Show simple item record
Search DSpace
Browse
-
All of DSpace
-
This Collection
My Account
Statistics
Compartilhar