Sistema de Monitoramento para Identificação de Contaminantes Apolares em Águas Subterrâneas via Condutividade Elétrica
Show simple item record
dc.contributor |
Universidade Federal de Santa Catarina |
pt_BR |
dc.contributor.advisor |
Flesch, Rodolfo César Costa |
|
dc.contributor.author |
Nunes, Nicolas Teixeira |
|
dc.date.accessioned |
2019-08-23T18:09:48Z |
|
dc.date.available |
2019-08-23T18:09:48Z |
|
dc.date.issued |
2019 |
|
dc.identifier.uri |
https://repositorio.ufsc.br/handle/123456789/200132 |
|
dc.description |
TCC(graduação) - Universidade Federal de Santa Catarina. Centro Tecnológico. Engenharia de Controle e Automação. |
pt_BR |
dc.description.abstract |
Um dos grandes problemas na indústria do petróleo é a detecção de anomalias geoquímicas
pela contaminação por hidrocarbonetos de petróleo e salinização de aquíferos, visto que
tal detecção normalmente é efetuada laboratorialmente, utilizando equipamentos de alto
custo, com análises sazonais da água subterrânea. Visando contornar tal dificuldade, este
trabalho apresenta a implementação de um sistema de monitoramento que utiliza como
parâmetro a condutividade elétrica da água subterrânea para detecção de anomalias
geoquímicas pela presença de contaminação por derivados de petróleo ou água salgada.
Como muitas das regiões de risco são situadas em áreas remotas, o sistema foi desenvolvido
para ter funcionamento independente, por isso conta com alimentação por energia solar,
processamento embarcado e comunicação sem fio por rede de telefonia celular entre a
unidade de campo e um sistema supervisório. Todos os dados coletados pelo sistema podem
ser analisados no supervisório, o qual conta com detalhamento dos dados por meio de
gráficos e estatísticas, geração automática de relatórios e alarmes que podem ser enviados
por e-mail. O sistema pode também ser programado para enviar mensagens de texto
diretamente para números de celular cadastrados para atuação imediata dos envolvidos
em caso de alarme crítico de contaminação. Este foi avaliado em ambiente laboratorial e
atendeu o propósito do desenvolvimento de identificação da contaminação de derivados
de petróleo em fase livre e água salgada, geração automática de alertas, após o sistema
apresentar possível contaminação do meio, e geração de relatórios detalhados sobre todas
as variáveis do sistema. |
pt_BR |
dc.description.abstract |
One of the major problems in the petroleum industry is the detection of geochemical
anomalies due to the contamination of petroleum hydrocarbons and salinization of aquifers,
since such detection is usually carried out in laboratories using high cost equipment
with seasonal analyzes of groundwater. In order to overcome this difficulty, this work
presents the implementation of a monitoring system that uses the electrical conductivity of
groundwater for the detection of geochemical anomalies by the presence of contamination
by petroleum derivatives or salt water. As many of the risk regions are located in remote
areas, the system was developed to operate independently, so it has solar power, embedded
processing and wireless communication by cellular telephone network between the field
unit and a supervisory system . All the data collected by the system can be analyzed
in the supervisory, which counts with detail of the data through graphs and statistics,
automatic generation of reports and alarms that can be sent by email. The system can
also be programmed to send text messages directly to registered mobile numbers for
the immediate action of those involved in case of critical contamination alarm. This
was evaluated in laboratory environment and met the purpose of the development of
identification of the contamination of petroleum derivatives in free phase and salt water,
automatic generation of alerts, after the system present possible contamination of the
environment, and generation of detailed reports on all variables of the system. |
pt_BR |
dc.language.iso |
pt_BR |
pt_BR |
dc.publisher |
Florianópolis, SC. |
pt_BR |
dc.rights |
Open Access |
|
dc.subject |
Sistema de monitoramento. Água subterrânea. Condutividade elétrica. Contaminação por hidrocarbonetos e cloreto de sódio. |
pt_BR |
dc.subject |
Monitoring system. Underground water. Electric conductivity. Contamination by hydrocarbons and sodium chloride. |
pt_BR |
dc.title |
Sistema de Monitoramento para Identificação de Contaminantes Apolares em Águas Subterrâneas via Condutividade Elétrica |
pt_BR |
dc.type |
TCCgrad |
pt_BR |
Files in this item
This item appears in the following Collection(s)
Show simple item record
Search DSpace
Browse
-
All of DSpace
-
This Collection
My Account
Statistics
Compartilhar