dc.description TCC(graduação) - Universidade Federal de Santa Catarina. Centro Tecnológico. Engenharia Sanitária e Ambiental. pt_BR
dc.description.abstract A água é um bem essencial para a manutenção da vida de todos os organismos. No entanto, muitos lugares sofrem com a falta de água potável, seja devido ao crescimento acentuado da população, às mudanças climáticas e/ou à má gestão dos recursos hídricos. Contrapondo isto, de acordo com SNIS (2018), tem-se que aproximadamente 40% da água tratada é perdida seja por vazamentos, fraudes e erros de medição. Assim, a redução de perdas nos sistemas de abastecimento de água torna-se essencial pois, além de otimizar o aproveitamento dos recursos hídricos, também traz benefícios financeiros e operacionais para a companhia de saneamento. O objetivo deste trabalho foi avaliar a metodologia para controle de perdas em um Distrito de Medição e Controle no município de Florianópolis e o potencial de melhorias nos procedimentos utilizados. Desta forma, através dos indicadores de desempenho, vazão mínima noturna e fator de pesquisa, foi possível entender a situação atual do Distrito de Medição e Controle (DMC). Após essa análise, identificou-se que o DMC possuía elevado índice de perdas, que a vazão mínima noturna poderia ser reduzida e que o setor possuía elevado fator de pesquisa, indicando que a probabilidade de estarem ocorrendo vazamentos era maior. No DMC também foi realizado um levantamento da situação atual do parque de hidrômetros, onde constatou-se que 51% apresentavam idade superior a 5 anos. Assim, foi proposto realizar a troca de 101 hidrômetros considerando os critérios adotados pela Companhia. Assim, para o controle e redução de perdas, a pressão de recalque do booster foi reduzida, diminuindo em 16% o volume disponibilizado, em 30% a vazão mínima noturna e em 14% o índice de perdas por ligação. Neste trabalho também estavam previstas ações de geofonamento, fiscalização comercial e troca dos hidrômetros, no entanto, devido à pandemia por COVID-19, não foi possível realizar essas atividades em tempo hábil. pt_BR
dc.description.abstract Water is an essential asset for the maintenance of life for all organisms. However, many places suffer from a lack of drinking water, either due to the sharp growth of the population, climate changes and/or poor management of water resources. In contrast, according to SNIS (2018), 40% of the treated water is lost due to leakages, fraud and measurement errors. Therefore, reducing losses in water supply systems is essential because, in addition to reducing uncontrolled use of water resources, it also brings financial and operational benefits to the sanitation company. The objective of this undergraduate final project was to evaluate the methodology for loss control in a Measurement and Control District in the city of Florianópolis and the potential for improvements in the procedures used. Thus, through the performance indicators, minimum night flow rate method and research factor, it was possible to understand the current situation of the Measurement and Control District (MCD). After this analysis, it was identified that the MCD had a high rate of losses, the minimum night flow rate could be reduced and the sector had a high research factor, indicating that the probability of leakages occurrence was higher. At the MCD, a survey of the current situation of the water meter park was also carried out, where it was found that 51% were over the age of 5 years. Therefore, it was proposed to replace 101 water meters considering the criteria adopted by the Company. Thus, for the control and reduction of losses, the pressure of booster repression was reduced, where the volume produced could be reduced in 16% and the minimum night flow rate in 30%. In this work, actions were also planned for geophoning, commercial inspection and replacement of water meters, however, due to the pandemic by COVID-19, it was not possible to carry out these activities in time. pt_BR
dc.format.extent 46 f. pt_BR
dc.language.iso pt_BR pt_BR
dc.publisher Florianópolis, SC. pt_BR
dc.rights Open Access
dc.subject Sistemas de Abastecimento de Água pt_BR
dc.subject Controle de Perdas de Água pt_BR
dc.subject Indicadores de Desempenho pt_BR
dc.subject Balanço Hídrico pt_BR
dc.title Avaliação de Metodologia para Gestão de Perdas em um Distrito de Medição e Controle no Município de Florianópolis/SC pt_BR