Levantamento experimental do gradiente térmico de módulos fotovoltaicos com foco na aplicação do algoritmo de rastreamento do ponto de máxima potência baseado na medição de temperatura
Show simple item record
dc.contributor |
Universidade Federal de Santa Catarina |
pt_BR |
dc.contributor.advisor |
Coelho, Roberto Francisco |
|
dc.contributor.author |
Borges, Alberto Besen |
|
dc.date.accessioned |
2020-12-10T14:43:08Z |
|
dc.date.available |
2020-12-10T14:43:08Z |
|
dc.date.issued |
2020-11-20 |
|
dc.identifier.uri |
https://repositorio.ufsc.br/handle/123456789/218251 |
|
dc.description |
TCC (graduação) - Universidade Federal de Santa Catarina. Centro Tecnológico. Engenharia Elétrica. |
pt_BR |
dc.description.abstract |
O presente trabalho de conclusão de curso tem como finalidade projetar, confeccionar
e ensaiar um sistema de medição de temperatura de módulos fotovoltaicos com intuito
de determinar o gradiente térmico em suas células. O arranjo para mensuração da temperatura
é composto por uma placa de circuito impresso capaz de suportar a conexão
de até 72 sensores termosensíveis, que indicam a temperatura da célula fotovoltaica a
qual estão fixados. O processamento dos dados provenientes dos sensores é realizado
por nove microcontroladores STM32F103C8T6, que podem armazenar as informações
coletadas, assim como o horário das coletas, em uma memória micro-Secure Digital
(SD) externa. Para obtenção do gradiente térmico do módulo são efetuados o total
de quatro ensaios ao ar livre, considerando o emprego de um módulo fotovoltaico
KC200GT com inclinações de 45°e paralela ao solo, e orientação voltada ao norte
geográfico. Para comprovar a precisão e a confiabilidade dos dados provenientes do
sistema de aquisição desenvolvido, utiliza-se como referência o sistema de medição
comercial Profitest-PV©. Os resultados obtidos revelam que o módulo fotovoltaico
ensaiado apresenta gradiente térmico com variações que ultrapassam 10 °C e distribuição
térmica mais elevada nas células da parte esquerda do módulo. Revelam
também que a probabilidade de que seja selecionada aleatoriamente uma célula cuja
temperatura excede a média em até um desvio padrão, é de 68,26%. Apesar das
variações mencionadas, a conclusão é de que o máximo desvio da potência rastreada
pelo algoritmo de rastreamento baseado na medição de temperatura, em relação à
potência máxima, é de 1%, e acontece quando a célula selecionada para que se realize
a medição de temperatura, se localiza na região mais quente ou mais fria do módulo. |
pt_BR |
dc.description.abstract |
The purpose of this Undergraduate thesis is to design, manufacture and test a temperature
measurement system for photovoltaic modules in order to determine the thermal
gradient in its cells. The temperature measurement arrangement consists of a printed
circuit board capable of supporting the connection of up to 72 thermosensitive sensors,
which indicate the temperature of the photovoltaic cell to which they are attached. The
data processing from the sensors is carried out by nine STM32F103C8T6 microcontrollers,
which can store the information collected, as well as the time of collection, in
an external micro-Secure Digital (SD) memory. To obtain the thermal gradient of the
module, a total of four outdoor tests are carried out, considering the use of a KC200GT
photovoltaic module with slopes of 45°and parallel to the ground, and orientation facing
the geographic north. To prove the accuracy and reliability of the data from the developed
acquisition system, the commercial measurement system Profitest-PV© is used
as a reference. The results obtained reveal that the tested photovoltaic module has a
thermal gradient with variations that exceed 10 °C and a higher thermal distribution in
the cells on the left side of the module. They also reveal that the probability that a cell
whose temperature exceeds the average by up to one standard deviation is randomly
selected is 68.26%. Despite the mentioned variations, the conclusion is that the maximum
deviation of the power tracked by the tracking algorithm based on the temperature
measurement, in relation to the maximum power, is 1%, and it happens when the cell
selected to perform the measurement of temperature is located in the hottest or coldest
region of the module. |
pt_BR |
dc.format.extent |
105 |
pt_BR |
dc.language.iso |
pt_BR |
pt_BR |
dc.publisher |
Florianópolis, SC |
pt_BR |
dc.rights |
Open Access |
|
dc.subject |
Módulo fotovoltaico |
pt_BR |
dc.subject |
Rastreamento do ponto de máxima potência |
pt_BR |
dc.subject |
Gradiente térmico |
pt_BR |
dc.subject |
STM32F103C8T6 |
pt_BR |
dc.title |
Levantamento experimental do gradiente térmico de módulos fotovoltaicos com foco na aplicação do algoritmo de rastreamento do ponto de máxima potência baseado na medição de temperatura |
pt_BR |
dc.type |
TCCgrad |
pt_BR |
Files in this item
This item appears in the following Collection(s)
Show simple item record
Search DSpace
Browse
-
All of DSpace
-
This Collection
My Account
Statistics
Compartilhar