Análise e simulação de intervenções em instalações do Sistema Interligado Nacional

DSpace Repository

A- A A+

Análise e simulação de intervenções em instalações do Sistema Interligado Nacional

Show simple item record

dc.contributor Universidade Federal de Santa Catarina pt_BR
dc.contributor.advisor Pacheco, Renato Lucas
dc.contributor.author Silva, Lucas Jardim
dc.date.accessioned 2022-05-12T12:52:48Z
dc.date.available 2022-05-12T12:52:48Z
dc.date.issued 2022-05-09
dc.identifier.uri https://repositorio.ufsc.br/handle/123456789/234361
dc.description TCC (graduação) - Universidade Federal de Santa Catarina. Centro Tecnológico. Engenharia Elétrica. pt_BR
dc.description.abstract Este trabalho apresenta três análises de simulações com desligamentos de equipamentos pertencentes ao Sistema Interligado Nacional. Os equipamentos que serão isolados eletricamente são, uma linha de transmissão de 138 kV que interliga a subestação de Blumenau para a subestação de Blumenau Dois, o transformador 1 de 525 kV/230 kV da subestação de Curitiba e por fim o barramento de 230 kV da subestação de Blumenau. Essas simulações estão relacionadas com os pedidos de intervenções no SIN por empresas de energia, para manutenção ou melhorias em instalações de geração, transmissão e distribuição de energia elétrica, assim mantendo a qualidade e a continuidade da mesma. As análises de intervenções são baseadas nos critérios do procedimento de rede 2.3 do ONS – Premissas, critérios e metodologia para estudos elétricos. Esses procedimentos são importantes para que se escolha os melhores momentos para a realização dessas intervenções sem por em risco o Sistema Interligado Nacional. É utilizando o programa computacional Anarede para simular o fluxo de potência do SIN com esses equipamentos desligados. Será verificado que para a linha de transmissão e o barramento o melhor dia para ocorrer à intervenção é no domingo, pois a carga do sistema é menor. Para a intervenção com desligamento do transformador é possível ser realizado em dia de semana. pt_BR
dc.description.abstract This work presents three analyzes of simulations with shutdowns of equipment belonging to the National Interconnected System. The equipment that will be electrically isolated are a 138 kV transmission line that interconnects the Blumenau substation to the Blumenau Dois substation, the 525 kV/230 kV transformer 1 of the Curitiba substation and finally the 230 kV bus from the Blumenau substation. These simulations are related to requests for interventions in the SIN by energy companies, for maintenance or improvements in electric energy generation, transmission, and distribution facilities, thus maintaining its quality and continuity. Intervention analyzes are based on the criteria of the ONS network procedure 2.3 – Assumptions, criteria, and methodology for electrical studies. These procedures are important for choosing the best moments to carry out these interventions without jeopardizing the National Interconnected System. It is using the computer program Anarede to simulate the power flow of the SIN with these equipments turned off. It will be verified that for the transmission line and for the bus the best day for the intervention to occur is on Sunday, as the system load is lower. Intervention with transformer shutdown can be carried out on weekday pt_BR
dc.format.extent 57 f. pt_BR
dc.language.iso pt_BR pt_BR
dc.publisher Florianópolis, SC pt_BR
dc.rights Open Access
dc.subject Fluxo de Potência pt_BR
dc.subject Anarede pt_BR
dc.subject Sistema Interligado Nacional pt_BR
dc.subject Intervenções pt_BR
dc.subject Power Flow pt_BR
dc.subject National Interconnected System pt_BR
dc.subject Intervention pt_BR
dc.title Análise e simulação de intervenções em instalações do Sistema Interligado Nacional pt_BR
dc.type TCCgrad pt_BR