Valores normativos para o teste de sentar e levantar da cadeira de cinco repetições em idosos comunitários

DSpace Repository

A- A A+

Valores normativos para o teste de sentar e levantar da cadeira de cinco repetições em idosos comunitários

Show simple item record

dc.contributor Universidade Federal de Santa Catarina pt_BR
dc.contributor.advisor Avelar, Núbia Carelli Pereira de
dc.contributor.author Borba, Maria Carolina Borges de
dc.date.accessioned 2022-08-02T19:31:50Z
dc.date.available 2022-08-02T19:31:50Z
dc.date.issued 2022-07-26
dc.identifier.uri https://repositorio.ufsc.br/handle/123456789/237606
dc.description TCC(graduação) - Universidade Federal de Santa Catarina. Araranguá. Fisioterapia. pt_BR
dc.description.abstract O teste de sentar e levantar da cadeira de cinco repetições (TSLC5rep) é de fácil administração, possui validação e confiabilidade. Valores de referência podem variar em populações com características sócio-demográficas e antropométricas distintas. O presente estudo buscou estabelecer valores normativos para o TSLC5rep em idosos comunitários de acordo com sexo e faixa etária. Os achados do presente estudo podem servir como estratégia de detecção de déficits funcionais iniciais, permitindo o direcionamento sobre a necessidade de intervenções precoces de reabilitação em idosos residentes no Brasil. Objetivo: Estabelecer valores normativos para o TSLC5rep em idosos comunitários. Métodos: Estudo transversal com amostragem aleatória, realizado com 308 idosos comunitários (60 anos ou mais) de ambos os sexos. O TSLC5rep foi realizado mensurando o tempo que o voluntário levou para levantar e sentar da cadeira por 5 repetições. A análise dos resultados do TSLC5rep foi realizada em percentis estratificados por sexo e faixa etária. Resultados: O desempenho no teste variou de 8,08s a 39,97s entre as mulheres e de 7,07s a 29,74s entre os homens. As mulheres apresentaram tempo médio para a realização do TSLC5rep de 14,88s (60-69 anos), 14,93s (70-79 anos) e 19,67s (80 anos ou mais), enquanto os homens apresentaram tempo médio de 12,56s (60-69 anos), 15,47s (70-79 anos) e 15,10s (80 anos ou mais). Conclusão: Os valores normativos estabelecidos podem ser utilizados para interpretação do TSLC5rep na prática clínica. pt_BR
dc.description.abstract The five-repetition sit-and-stand test (TSLC5rep) is easy to administer and has validation and high reliability. Reference values could vary in populations with distinct sociodemographic and anthropometric characteristics. The present study sought to establish normative values for the TSLC5rep in community-dwelling elderly people according to sex and age group. The findings of the study serve as a strategy for detecting early functional deficits, allowing guidance on the need for early rehabilitation interventions in elderly people living in Brazil. Objective: To establish normative values for the TSLC5rep in community-dwelling elderly. Methods: Cross-sectional study with sampling randomized study, carried out with 308 community-dwelling elderly people (60 years and over) of both sexes. The TSLC5rep was performed by measuring the time that the volunteer took to get up and sit down from the chair for 5 repetitions. The analysis of the TSLC5rep results was performed in percentiles stratified by sex and age group. Results: Test performance ranged from 8.08s to 39.97s among women and from 7.07s to 29.74s among men. Women had an average time to perform of TSLC5rep of 14.88s (60-69 years), 14.93s (70-79 years), and 19.67s (80 years and over), while men had a mean time of 12.56s (60-69 years), 15.47s (70-79 years) and 15.10s (80 years and over). Conclusion: The established normative values could be used to interpret the TSLC5rep in clinical practice. pt_BR
dc.format.extent 25 f. pt_BR
dc.language.iso pt_BR pt_BR
dc.publisher Araranguá, SC pt_BR
dc.rights Open Access pt_BR
dc.subject TSLC5rep pt_BR
dc.subject Valor normativo pt_BR
dc.subject Déficits funcionais pt_BR
dc.title Valores normativos para o teste de sentar e levantar da cadeira de cinco repetições em idosos comunitários pt_BR
dc.type Article pt_BR


Files in this item

Files Size Format View Description
TCC II - Maria ... e Borba (versão final).pdf 1.201Mb PDF View/Open TCC - Maria Carolina

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Browse

My Account

Statistics

Compartilhar