Análise dos Efeitos da Moldagem de Hastes Longitudinais de Implantes de Estabilização da Coluna Vertebral Humana

DSpace Repository

A- A A+

Análise dos Efeitos da Moldagem de Hastes Longitudinais de Implantes de Estabilização da Coluna Vertebral Humana

Show simple item record

dc.contributor Universidade Federal de Santa Catarina. pt_BR
dc.contributor.advisor Roesler, Carlos Rodrigo de Mello
dc.contributor.author Holleweger, Maria Mária Job
dc.date.accessioned 2022-10-05T13:35:43Z
dc.date.available 2022-10-05T13:35:43Z
dc.date.issued 2022-09-15
dc.identifier.uri https://repositorio.ufsc.br/handle/123456789/240420
dc.description TCC (graduação) - Universidade Federal de Santa Catarina, Centro Tecnológico, Engenharia de Materiais. pt_BR
dc.description.abstract Foi realizada pesquisa bibliográfica dos efeitos da moldagem em hastes pediculares com enfoque nos resultados da literatura para hastes de liga de CoCr, titânio e liga de titânio. Foram encontrados resultados superiores de propriedades mecânicas da liga de CoCr após moldagem quando comparada ao titânio e titânio ligado, o que foi associado à suscetibilidade ao entalhe existente para o titânio e titânio ligado. Além da necessidade de maior caracterização microestrutural dos materiais empregados para fabricação de hastes pediculares para desenvolvimento de possíveis melhorias destes materiais quando moldados, conclui-se que o entalhe apresenta impacto significativo nos resultados encontrados pelos estudos o que indica a necessidade de busca por outros instrumentais de moldagem além do French Bender que evitem o dano à superfície das hastes e minimizem a iniciação de trincas. pt_BR
dc.description.abstract A literature search of the effects of pedicle rods contouring was performed focusing on literature results for CoCr alloy, pure titanium, and titanium alloy rods. Superior results were found for mechanical properties of CoCr alloy after contouring when compared to titanium and titanium alloy, which was associated with titanium and titanium alloy notch susceptibility. In addition to the need for further microstructural characterization of the materials used for the manufacture of pedicle rods in order to develop possible improvements of such materials when contoured, it is also observed that the notch has a significant impact on the results reported by the studies, which indicates the need to develop other contouring instruments besides the French Bender to avoid the damage to the rod surface and minimize the initiation of cracks. pt_BR
dc.format.extent 73 pt_BR
dc.language.iso pt_BR pt_BR
dc.publisher Florianópolis, SC. pt_BR
dc.rights Open Access. en
dc.subject Hastes pediculares pt_BR
dc.subject Moldagem pt_BR
dc.subject Entalhe pt_BR
dc.title Análise dos Efeitos da Moldagem de Hastes Longitudinais de Implantes de Estabilização da Coluna Vertebral Humana pt_BR
dc.type TCCgrad pt_BR
dc.contributor.advisor-co Pocovi, Carolini de Souza