dc.description.abstract |
A presente pesquisa tem por objetivo identificar o conforto térmico promovido por estratégias
convencionais de ventilação natural em salas de aula da Zona Bioclimática 2. Também visa a verificar
quais estratégias viabilizam taxas de ventilação adequadas, tendo em vista o contexto de disseminação
da doença do COVID-19. Foram realizadas simulações no software EnergyPlus, versão 8.9.0, para a
obtenção das temperaturas operativas na sala de aula, que foi configurada com 8 condições distintas de
ventilação natural. Também foi aplicada a equação proposta na EN 16798-1 para estimar a taxa de
ventilação no modelo. Os resultados mostraram que as estratégias de ventilação cruzada são mais
satisfatórias para a sala de aula analisada, pois viabilizaram taxas de ventilação adequadas às
recomendações da OPAS. Porém, quando houve uso de ventilação cruzada e higiênica, foi identificado
considerável desconforto térmico, em virtude da redução da temperatura operativa no ambiente. |
pt_BR |
dc.description.abstract |
This research aims to identify the thermal comfort promoted by conventional natural ventilation
strategies in classrooms in Bioclimatic Zone 2. It also aims to verify which strategies enable adequate
ventilation rates, considering the context of COVID-19 disease dissemination. Simulations were
carried out in the EnergyPlus software, version 8.9.0, to obtain the operating temperatures in the
classroom, which was configured with 8 different conditions of natural ventilation. The equation
proposed in EN 16798-1 was also applied to estimate the ventilation rate in the model. The results
showed that cross ventilation strategies are more satisfactory for the analyzed classroom, as they
enabled ventilation rates that were adequate to the PAHO recommendations. However, when cross
ventilation and hygienic ventilation were used, considerable thermal discomfort was identified, due to
the reduction of the operating temperature in the environment. |
pt_BR |
dc.language.iso |
por |
pt_BR |
dc.publisher |
Grupo de Pesquisa Virtuhab/ UFSC |
pt_BR |
dc.subject |
Ventilação Natural; |
pt_BR |
dc.subject |
Conforto Térmico; |
pt_BR |
dc.subject |
Qualidade da ventilação; |
pt_BR |
dc.subject |
Salas de Aula. |
pt_BR |
dc.subject |
Natural Ventilation; Thermal Comfort; Ventilation Quality; Classrooms. |
pt_BR |
dc.title |
Análise do conforto térmico e da qualidade da ventilação interna em salas de aula naturalmente ventiladas da Zona Bioclimática 2 |
pt_BR |
dc.title.alternative |
Analysis of thermal comfort and quality of indoor ventilation in naturally ventilated classrooms in Bioclimatic Zone 2 |
pt_BR |
dc.type |
Article |
pt_BR |
Files in this item
This item appears in the following Collection(s)
Show simple item record
Search DSpace
Browse
-
All of DSpace
-
This Collection
My Account
Statistics
Compartilhar