dc.description.abstract Sistemas e aplicações que reduzem custo são prioridade na indústria devido à severa inflação global e crise de insumos. Nessa ótica, um maciço investimento em tecnologias de monitoramento em tempo real configura-se como saídas para mitigar gastos e aprimorar técnicas. Tais fatores impactam diretamente no valor ao final do produto. A proposta desse trabalho é aplicar o dispositivo desenvolvido na dissertação de Paula Lima (2021) para monitorar o processo de cura do cimento, por meio do fluxo de calor proveniente das reações químicas exotérmicas após a hidratação da mistura. A técnica embarcada no dispositivo é o método do fio quente que mede a variação da resistência por meio de um PT100 acoplado na amostra. Os dados coletados foram comparados com o gráfico teórico para tentar estabelecer uma relação e estimar a cura. Com o auxilio de um sensor capacitivo comercial para medir a umidade do solo, é registrado a variação da capacitância na amostra para contrastar com os resultados obtidos. Por meio do resultado espera-se reduzir o uso de materiais em construções e viabilizar um monitoramento sem usar blocos de controle para aferir a umidade interna, com ganho de espaço e redução do desperdiço de matérias. pt_BR
dc.description.abstract Systems and applications that reduce costs are a priority in the industry due to severe global inflation and input crisis. In this perspective, a massive investment in real-time monitoring technologies is seen as a way to mitigate expenses and improve techniques. These factors directly impact the final product value. The purpose of this work is to apply the device developed in Paula Lima's dissertation (2021) to monitor the curing process of cement through the heat flow resulting from exothermic chemical reactions after the hydration of the mixture. The technique embedded in the device is the hot wire method, which measures resistance variation through a PT100 attached to the sample. The collected data were compared to the theoretical graph in an attempt to establish a relationship and estimate the curing process. With the aid of a commercial capacitive sensor to measure soil moisture, the variation in capacitance in the sample is recorded to contrast with the obtained results. The outcome is expected to reduce the use of materials in constructions and enable monitoring without the need for control blocks to measure internal moisture, thereby saving space and reducing material waste. pt_BR
dc.format.extent 36 f. pt_BR
dc.language.iso por pt_BR
dc.publisher Joinville, SC. pt_BR
dc.rights Open Access. en
dc.subject Sensor resistivo pt_BR
dc.subject Sensor capacitivo pt_BR
dc.subject Coleta de dados pt_BR
dc.subject Resistive sensor pt_BR
dc.subject Capacitive sensor pt_BR
dc.subject Data collect pt_BR
dc.title Monitoramento do processo de cura do cimento usando PT100 pt_BR
dc.type TCCgrad pt_BR


Files in this item

Files Size Format View Description
TCC.pdf 11.58Mb PDF View/Open TCC_Lucas

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Browse

My Account

Statistics

Compartilhar