Avaliação de sistemas de lodo ativado aplicados como tratamento de esgoto sanitário em condomínios residenciais

DSpace Repository

A- A A+

Avaliação de sistemas de lodo ativado aplicados como tratamento de esgoto sanitário em condomínios residenciais

Show simple item record

dc.contributor Universidade Federal de Santa Catarina. pt_BR
dc.contributor.advisor Junior, Nelson Libardi
dc.contributor.author Garcia, Luiz Carlos Pierozan
dc.date.accessioned 2023-07-10T20:24:58Z
dc.date.available 2023-07-10T20:24:58Z
dc.date.issued 2023-07-04
dc.identifier.uri https://repositorio.ufsc.br/handle/123456789/248489
dc.description TCC (graduação) - Universidade Federal de Santa Catarina, Centro Tecnológico, Engenharia Sanitária e Ambiental. pt_BR
dc.description.abstract A disposição inadequada e o tratamento inadequado do esgoto sanitário implicam em perda de qualidade de vida, problemas de saúde e dificuldade em desfrutar de um espaço comum de qualidade para a população local. Este trabalho consiste em estudar duas estações de tratamento de esgoto do tipo lodos ativados em dois condomínios localizados no município de Florianópolis para tratar esgoto doméstico. O objetivo é avaliar o controle operacional, estrutura, biomassa e eficiência na remoção de parâmetros como demanda bioquímica de oxigênio, fósforo total e nitrogênio amoniacal. Foram utilizados dados secundários da operação das estações de tratamento de esgoto, bem como dados primários obtidos em análises laboratoriais, incluindo séries de sólidos suspensos no tanque de aeração, respirometria e microscopia do lodo ativado. Observou-se que as maiores concentrações de sólidos suspensos voláteis obtidas nos reatores para ETE 1 e ETE 2, 525 mg/L e 544 mg/L, respectivamente, estão abaixo dos valores recomendados na literatura e nos critérios de projeto. A respirometria indicou uma proporção elevada de microorganismos heterotróficos em relação aos autotróficos. A análise microscópica do lodo ativado revelou uma abundância de microorganismos do gênero Epistylis e baixa diversidade microbiana. Concluiu-se que a operação das estações de tratamento de esgoto do tipo lodos ativados depende dos equipamentos eletromecânicos instalados, que devem atender às necessidades operacionais e permitir a automação do sistema. Além disso, as análises realizadas desempenham um papel crucial ao fornecer informações relevantes para a tomada de decisões e contribuem significativamente para a operação eficiente do sistema. pt_BR
dc.description.abstract The improper and untreated disposal of sanitary sewage implies a loss of quality of life, health problems, and difficulty in enjoying a quality common space for the local population. This work consists of studying two activated sludge wastewater treatment plants in two condominiums located in the municipality of Florianópolis to treat domestic sewage. The objective is to evaluate the operational control, structure, biomass, and efficiency in removing parameters such as biochemical oxygen demand, total phosphorus, and ammoniacal nitrogen. Secondary data from the operation of the wastewater treatment plants, as well as primary data obtained from laboratory analyses, including suspended solids series in the aeration tank, respirometry, and microscopy of the activated sludge, were used. It was observed that the higher concentrations of volatile suspended solids obtained in the reactors for ETE 1 and ETE 2, 525 mg/L and 544 mg/L, respectively, are below the values recommended in the literature and the design criteria. Respirometry indicated a high proportion of heterotrophic microorganisms compared to autotrophic microorganisms. Microscopic analysis of the activated sludge revealed an abundance of Epistylis microorganisms and low microbial diversity. It is concluded that the operation of activated sludge wastewater treatment plants depends on the electromechanical equipment installed, which must meet operational needs and enable system automation. Additionally, the performed analyses play a crucial role in providing relevant information for decision-making and significantly contribute to the efficient operation of the system. pt_BR
dc.format.extent 115 f. pt_BR
dc.language.iso pt_BR pt_BR
dc.publisher Florianópolis, SC. pt_BR
dc.rights Open Access. en
dc.subject estação de tratamento de esgoto pt_BR
dc.subject lodos ativados pt_BR
dc.subject controle operacional pt_BR
dc.subject wastewater treatment plant pt_BR
dc.subject activated sludge pt_BR
dc.subject operational control pt_BR
dc.title Avaliação de sistemas de lodo ativado aplicados como tratamento de esgoto sanitário em condomínios residenciais pt_BR