dc.contributor |
Universidade Federal de Santa Catarina. |
pt_BR |
dc.contributor.advisor |
Cubillos, Patricia Ortega |
|
dc.contributor.author |
Rosa, Marina Dias |
|
dc.date.accessioned |
2023-07-25T17:24:22Z |
|
dc.date.available |
2023-07-25T17:24:22Z |
|
dc.date.issued |
2023-07-19 |
|
dc.identifier.uri |
https://repositorio.ufsc.br/handle/123456789/249108 |
|
dc.description |
TCC (graduação) - Universidade Federal de Santa Catarina, Centro Tecnológico, Engenharia de Materiais. |
pt_BR |
dc.description.abstract |
Nesta pesquisa foi realizado um estudo do contexto atual dos registros de artroplastias
parciais de ombro, a partir de relatórios publicados por centros de registro
mundialmente referenciados. A partir de revisão da literatura, este estudo propôs uma
metodologia de retrieval analysis para componentes de próteses parciais de ombro –
cabeça umeral e haste umeral, com o objetivo de protocolar o procedimento para o
Centro Nacional de Análise de Explantes – CNAEx. A metodologia proposta consiste
nas etapas de coleta, limpeza, registro e análise macrográfica de explantes. O
procedimento experimental consistiu na aplicação da metodologia desenvolvida em
três amostras de próteses parciais de ombro disponibilizadas pelo Instituto Nacional
de Ortopedia e Traumatologia - INTO. As etapas de coleta e limpeza foram executadas
na unidade hospitalar parceira. Ao serem recebidas no CNAEx, as amostras foram
identificadas de acordo com o método de rastreabilidade de dados desenvolvido, e
foram registradas com base na estrutura dos registros revisados. Os registros de
procedimentos de revisão de artroplastia de ombro apresentaram uma tendência
equivalente quanto ao perfil dos pacientes: majoritariamente do sexo feminino, média
de 70 anos. Os dados clínicos dos pacientes aos quais as amostras recebidas para
este estudo foram explantadas, ainda não permitem estabelecer nenhuma tendência
para o CNAEx. Por fim, foram aplicados os métodos para a análise de danos nos
explantes, primeiramente com a obtenção de imagens macroscópicas por
estereoscópio ótico, seguida da avaliação de severidade de danos. A avaliação de
danos das amostras indicou maior severidade de corrosão e desgaste nos explantes
de ombro fabricados em aço inoxidável. Na metodologia desenvolvida para a
avaliação de severidade de fretting corrosion foi levado em consideração o
posicionamento no paciente, aspecto inovador e não observado em trabalhos
similares semelhantes de retrieval analysis para próteses de ombro. |
pt_BR |
dc.description.abstract |
In this research, a study of the current context of partial shoulder arthroplasty registries
was carried out, based on reports published by globally referenced registry centers.
Based on a literature review, this study proposed a retrieval analysis methodology for
components of partial shoulder prostheses - humeral head and humeral stem, with the
objective of protocolizing the procedure for the Centro Nacional de Análise de
Explantes - CNAEx. The proposed methodology consists of the steps of collection,
cleaning, registration and macrographic analysis of explants. The experimental
procedure consisted in the application of the developed methodology in three samples
of partial shoulder prostheses provided by the Instituto Nacional de Traumatologia e
Ortopedia - INTO. The collect and cleaning steps were performed at the partner
hospital unit. Upon receipt at the CNAEx, the samples were identified according to the
developed data traceability method, and were registered based on the structure of the
reviewed records. The records of shoulder arthroplasty revision procedures showed
an equivalent trend in terms of patient profile: mostly female, mean age 70 years. The
clinical data of the patients from whom the samples received for this study were
explanted do not yet allow any trend to be established for CNAEx. Finally, the methods
for damage analysis of the explants were applied, first by obtaining macroscopic
images by optical stereoscope, followed by damage severity assessment. The damage
assessment of the samples indicated greater severity of corrosion and wear in the
shoulder explants made of stainless steel. In the methodology developed for the
assessment of fretting corrosion severity, the positioning in the patient was taken into
account, an innovative aspect not observed in similar retrieval analysis works for
shoulder prostheses. |
pt_BR |
dc.language.iso |
pt_BR |
pt_BR |
dc.publisher |
Florianópolis, SC. |
pt_BR |
dc.rights |
Open Access. |
en |
dc.subject |
Artroplastia |
pt_BR |
dc.subject |
Artroplastia parcial de ombro |
pt_BR |
dc.subject |
Registro |
pt_BR |
dc.subject |
Retrieval analysis |
pt_BR |
dc.subject |
Metodologia |
pt_BR |
dc.subject |
Fretting-corrosion |
pt_BR |
dc.subject |
Mecanismos de danos |
pt_BR |
dc.subject |
Desgaste |
pt_BR |
dc.subject |
Corrosão |
pt_BR |
dc.title |
Retrieval analysis em próteses parciais de ombro: estudo preliminar |
pt_BR |
dc.type |
TCCgrad |
pt_BR |
dc.contributor.advisor-co |
Roesler, Carlos Rodrigo de Mello |
|