dc.description.abstract |
Moradias isoladas de países em desenvolvimento geralmente são desprovidas de tratamento e
abastecimento público de água. O filtro lento intermitente - FLI (BioSand Filter - BSF) é uma
tecnologia que pode ser empregada nesses lugares com objetivo de amenizar o problema do
acesso à água potável. Nesse sentido, esse trabalho tem como objetivo avaliar a influência de
uma esponja de poliuretano instalada na parte superior do meio filtrante de um filtro lento
intermitente, verificando a aclimatação do sistema, a eficiência de tratamento e o operacional
da unidade. Para isso, foram construídos, em escala piloto, dois filtros lentos intermitentes com
e sem esponja instalada na parte superior do meio filtrante. As duas unidades eram com
escoamento descendente, operando a uma taxa de filtração inicial de 400 L / m² h. Para a
avaliação da eficiência dos filtros, foram analisados os seguintes parâmetros: temperatura,
condutividade elétrica, sólidos totais dissolvidos, oxigênio dissolvido, pH, turbidez, cor
aparente e verdadeira, coliformes totais e Escherichia coli. Também foi observada a relação
entre a capacidade de retenção da turbidez pela esponja e a duração das carreiras de filtração.
Os resultados demonstraram que a utilização da esponja, resultou em remoções médias
superiores ao filtro sem esponja em relação à turbidez, cor aparente, cor verdadeira e
Escherichia coli. Durante o tempo de operação, de 169 dias, foram realizadas quatro carreiras
de filtração para o FLI sem esponja e apenas uma para o FLI com esponja, evidenciando menor
frequência de limpeza. Os resultados obtidos nesta pesquisa indicam a potencialidade do
emprego da esponja de poliuretano no tratamento de água para filtros lentos intermitentes, tendo
impacto na qualidade da água e na duração das carreiras de filtração. |
pt_BR |
dc.description.abstract |
Isolated houses in low income countries generally lack public water treatment and supply. The
intermittent slow filter (BioSand Filter - BSF) is a technology that can be applied in these places
in order to reduce the problem of access to drinking water. In this sense, this final paper aims
to evaluate the influence of a polyurethane sponge installed on the upper part of the filtering
layer of an intermittent slow filter, by verifying the system’s acclimation, its treatment
efficiency and the unit’s operation. To do so, two intermittent slow filters were built on a pilot
scale, one with and one without a sponge installed on the upper part of the filter layer. Both
units had downward flow, operating at an initial filtration rate of 400 L/m² h. To evaluate the
efficiency of the filters, the following parameters were analyzed: temperature, electrical
conductivity, total dissolved solids, dissolved oxygen, pH, turbidity, apparent and true color,
total coliforms and Escherichia coli. It was also observed the relationship between the sponge’s
turbidity retention capacity and the length of the filtration runs. The results have shown that the
use of the sponge resulted in higher average removals in comparison to the filter without a
sponge in terms of turbidity, apparent color, true color and Escherichia coli. During the 169
days operating time, four filtration runs were performed for the BSF without sponge and only
one for the BSF with sponge, which means a lower cleaning frequency. The results obtained in
this research indicate the potential use of polyurethane sponge in water treatment for
intermittent slow filters, having an impact on the water’s quality and the length of the filtration
runs. |
pt_BR |
dc.format.extent |
59 f. |
pt_BR |
dc.language.iso |
pt_BR |
pt_BR |
dc.publisher |
Florianópolis, SC. |
pt_BR |
dc.rights |
Open Access. |
en |
dc.subject |
Tratamento de água |
pt_BR |
dc.subject |
Filtro lento intermitente |
pt_BR |
dc.subject |
BioSand Filter |
pt_BR |
dc.subject |
Esponja de poliuretano |
pt_BR |
dc.subject |
Water treatment |
pt_BR |
dc.subject |
Intermittent slow filter |
pt_BR |
dc.subject |
BioSand Filter |
pt_BR |
dc.subject |
Polyurethane sponge |
pt_BR |
dc.title |
Influência de uma esponja de poliuretano instalada no meio filtrante de um filtro lento intermitente, com destaque para aclimatação do sistema |
pt_BR |
dc.type |
TCCgrad |
pt_BR |
dc.contributor.advisor-co |
Rodrigues, Ailton Borges |
|