Estratégias para detecção de faltas incipientes em geradores síncronos através do fluxo magnético no entreferro

DSpace Repository

A- A A+

Estratégias para detecção de faltas incipientes em geradores síncronos através do fluxo magnético no entreferro

Show simple item record

dc.contributor Universidade Federal de Santa Catarina
dc.contributor.advisor Batistela, Nelson Jhoe
dc.contributor.author Antunes, Luciano Bortoloto
dc.date.accessioned 2023-09-01T13:05:57Z
dc.date.available 2023-09-01T13:05:57Z
dc.date.issued 2023
dc.identifier.other 383222
dc.identifier.uri https://repositorio.ufsc.br/handle/123456789/249994
dc.description Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Elétrica, Florianópolis, 2023.
dc.description.abstract A parada não programada de um gerador síncrono em operação no sistema elétrico pode ocasionar perda de faturamento e de confiabilidade, além de gerar multas. Neste contexto, sistemas de monitoramento de condição de máquina são uma solução atraente, pois permitem a programação de manutenções preventivas de maneira otimizada. Este trabalho tem como objetivo propor estratégias de análises no domínio do tempo e da frequência para detecção e diferenciação de faltas incipientes em geradores síncronos através do fluxo magnético no entreferro e da corrente de excitação. Realizaram-se ensaios experimentais em uma bancada que permite a imposição de faltas de maneira controlada, aplicando as estratégias propostas. A robustez das estratégias de detecção foi avaliada nos testes com imposição de diferentes modos de falta em diversos pontos de operação na bancada. A análise de diferentes indicadores propostos mostrou a possibilidade de detectar, mensurar e diferenciar os defeitos em enrolamentos do estator e de excitação, bem como de excentricidade estática, independentemente do carregamento da máquina.
dc.description.abstract Abstract: The unscheduled stoppage of a synchronous generator operating in the electrical system may cause fines and loss of revenue and reliability. In this context, machine condition monitoring systems are an attractive solution, as they allow the scheduling of preventive maintenance in an optimized way. This work proposes analysis strategies in the time and frequency domain for detecting and differentiating incipient faults in synchronous generators through the air gap magnetic flux and the field current. Experimental tests were made on a bench that allows the imposition of faults in a controlled manner. The robustness of the detection strategies was evaluated in tests with the imposition of different fault modes at different operation points on the bench. The analysis of different proposed indicators showed the possibility of detecting, measuring and differentiating faults in the stator and excitation windings and static eccentricity, regardless of machine loading. en
dc.format.extent 116 p.| il., gráfs.
dc.language.iso por
dc.subject.classification Engenharia elétrica
dc.subject.classification Geradores síncronos
dc.subject.classification Circuitos magnéticos
dc.subject.classification Correntes elétricas
dc.subject.classification Transformadores de corrente para instrumentos
dc.title Estratégias para detecção de faltas incipientes em geradores síncronos através do fluxo magnético no entreferro
dc.type Dissertação (Mestrado)
dc.contributor.advisor-co Wengerkievicz, Carlos Alexandre Corrêa


Files in this item

Files Size Format View
PEEL2125-D.pdf 12.20Mb PDF View/Open

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Browse

My Account

Statistics

Compartilhar