dc.description.abstract |
O objetivo deste estudo foi avaliar o efeito do regime de radioterapia (50 Gy e 70 Gy) na
resistência ao deslocamento de cimentos endodônticos de diferentes bases. Quarenta e
cinco incisivos bovinos foram decoronados e noventa discos de dentina com 1 mm de
espessura dos terços cervical e médio (quarenta e cinco de cada) foram obtidos. Os discos
de dentina (terços cervical e médio) foram distribuídos em três grupos, de acordo com o
regime radioterápico (n=15): não irradiado; 50 Gy; e 70 Gy. Em seguida, três cavidades
semelhantes a canais radiculares de 1,0 mm de diâmetro foram realizadas em cada disco de
dentina. Após irrigação com solução de NaOCl à 2,5% e EDTA à 17%, cada cavidade foi
preenchida com os seguintes cimentos: AH Plus Jet, BioRoot RCS e Endofill (n=15).
Após 7 dias de armazenamento controlado em estufa à 37 graus celsius e 100% de
umidade relativa do ar, o teste de micro push-out foi realizado em Máquina Universal de
Ensaios. As falhas foram analisadas em estereomicroscópio. A análise estatística foi
realizada com testes de ANOVA de três fatores e post-hoc de Bonferroni (α=5%). Os
espécimes não-irradiados preenchidos com AH Plus Jet e BioRoot RCS apresentaram
valores de resistência de união superiores aos irradiados, independentemente do regime
de radioterapia (p<0,001). Não houve diferenças entre os espécimes irradiados com 50
Gy e 70 Gy, tanto para AH Plus Jet quanto para BioRoot RCS (p>0,05). Não houve
diferenças entre amostras não-irradiadas e irradiadas para Endofill no terço cervical
(p=0,406). O modo de falha coesiva foi o mais frequente antes da irradiação. Após a
irradiação, o mais frequente foi o adesivo. A radioterapia foi associada à menor resistência
de união micro push-out para os cimentos à base de resina epóxi e biocerâmico,
independentemente do regime radioterapia. O cimento à base de óxido de zinco
apresentou menor resistência de união. |
pt_BR |
dc.description.abstract |
The aim of this study was to evaluate effect of the radiation therapy regimen (50 Gy and
70 Gy) on the dislodgement resistance of endodontic sealers of different bases. Forty-five
bovine incisors were decoronated and ninety 1-mm thick dentin slices from the cervical
and middle thirds (forty-five of each) were obtained. The dentin slices (cervical and
middle thirds) were distributed into three groups, according to the radiation therapy
regimen (n=15): non-irradiated; 50 Gy; and 70 Gy. Next, three 1.0 mm diameter root
canal-like cavities were made in each dentin slice. After rinsing with 2.5% NaOCl
solution and 17% EDTA, each cavity was filled with the following sealers: AH Plus Jet,
BioRoot RCS and Endofill (n=15). After 7 days of controlled storage in an oven at 37
Celsius degress and 100% relativity humidity, a micro push-out test was performed in a
Universal Testing Machine. Failures were analyzed using a stereomicroscope. Statistical
analysis was performed with Three-Way ANOVA and Bonferroni's post-hoc test (α=5%)
tests. Non-irradiated specimens filled with AH Plus Jet and BioRoot RCS had higher bond
strength values than the irradiated ones, regardless of the radiation therapy regimen
(p<0.001). There were no differences between specimens irradiated with 50 Gy and 70
Gy, for both AH Plus Jet and BioRoot RCS (p>0.05). There were no differences among
non-irradiated and irradiated specimens for Endofill at the cervical third (p=0.406).
Cohesive failure mode was the most frequent before irradiation. After irradiation, the
most frequent was the mixed ones. Radiation therapy was associated with lower micro
push-out bond strength of epoxy resin and bioceramic sealers, regardless of the dose
regimen. The zinc oxide-based sealer had the lower micro push-out bond strength. |
pt_BR |
dc.format.extent |
46 |
pt_BR |
dc.language.iso |
en_US |
pt_BR |
dc.publisher |
Florianópolis, SC. |
pt_BR |
dc.rights |
Open Access. |
en |
dc.subject |
Cimento obturador |
pt_BR |
dc.subject |
Endodontia |
pt_BR |
dc.subject |
Obturação |
pt_BR |
dc.subject |
Resistência ao cisalhamento |
pt_BR |
dc.subject |
Radioterapia |
pt_BR |
dc.title |
Efeito do regime de radioterapia na resistência ao deslocamento de cimentos endodônticos de diferentes bases |
pt_BR |
dc.type |
TCCgrad |
pt_BR |
Files in this item
This item appears in the following Collection(s)
Show simple item record
Search DSpace
Browse
-
All of DSpace
-
This Collection
My Account
Statistics
Compartilhar