dc.contributor |
Universidade Federal de Santa Catarina. |
pt_BR |
dc.contributor.advisor |
Chaves, Eduardo S. |
|
dc.contributor.author |
Gonçalves, Caroline |
|
dc.date.accessioned |
2023-12-05T13:19:46Z |
|
dc.date.available |
2023-12-05T13:19:46Z |
|
dc.date.issued |
2023-12-04 |
|
dc.identifier.uri |
https://repositorio.ufsc.br/handle/123456789/252439 |
|
dc.description |
TCC (graduação) - Universidade Federal de Santa Catarina, Centro de Ciências Físicas e Matemáticas, Química. |
pt_BR |
dc.description.abstract |
Um método ambientalmente amigável foi desenvolvido, utilizando o procedimento de
extração assistida por ultrassom com solvente eutético profundo (DES-UAE) para a
determinação de chumbo (Pb) em cascalhos de poços de perfuração (CP) onshore e
offshore por espectrometria de absorção atômica em forno de grafite (GF AAS). Neste
estudo, 50 mg da amostra de cascalhos de poços de perfuração em 2,50 g de DES
diluído (30% m/m de água) foram submetidos a extração assistida por ultrassom
(UAE) a 80 ± 5 ºC durante 50 min. O efeito dos parâmetros de extração temperatura,
tempo e proporção de água no DES foram avaliados utilizando o modelo de
planejamento Box-Behnken. A concentração de chumbo foi determinada por GF AAS,
utilizando Pd (0,015 mg para um volume de injeção de 10 µL) como modificador
químico, nas temperaturas de pirólise de 900 ºC e atomização de 2100 ºC. Os
resultados demonstraram que o DES formado por cloreto de colina (ChCl) e ácido
oxálico (Oxa), numa razão molar de 1:1, utilizando UAE apresentou maior eficiência
de extração. Os limites de detecção (LOD) e quantificação obtidos foram 0,2 µg g-1 e
0,5 µg g-1
, respetivamente. A exatidão do método foi avaliada através da análise de
amostras certificadas, com valores de concordância na faixa de 104 a 106%, e
comparando os resultados com os obtidos após digestão ácida, sem diferença
significativa (teste t, a 95% de nível de confiança). As concentrações obtidas para os
poços foram de 1,64 - 168,39 µg g-1
(offshore) e de 1,14 - 2,98 µg g-1
(onshore). O
método foi aplicado para a determinação de Pb em amostras de cascalhos de poços
de perfuração de diferentes profundidades, tendo as concentrações de Pb obtidas
variando de 1,48 a 11,03 e de 131,67 a 168,39 µg g-1 para amostras de poços onshore
e offshore, respectivamente. Em relação aos princípios da química verde, o método
apresentou nota de 0,56, sendo superior ao método convencional de digestão ácida
em bloco digestor (0,38), atendendo a vários princípios da química analítica verde.
Sendo assim, o método DES-UAE para extração de Pb em CP mostrou ser eficaz,
simples e ambientalmente amigável. |
pt_BR |
dc.description.abstract |
An environmentally friendly method was developed using a deep eutectic solvent
ultrasound-assisted extraction procedure (DES-UAE) for lead (Pb) determination in
onshore and offshore drill cuttings (CP) by graphite furnace atomic absorption
spectrometry (GF AAS). In this study, 50 mg of the drill cutting sample in 2,50 g of
diluted DES (30% w/w of water) was subjected to ultrasound-assisted extraction (UAE)
at 80 ± 5 ºC for 50 min. The effects of the extraction parameters temperature, time,
and proportion of water in the DES were evaluated using the Box-Behnken
experimental design. Lead concentration was determined by GF AAS, using Pd (0,015
mg for an injection volume of 10 µL) as a chemical modifier at 900 ºC pyrolysis and
2100 ºC atomization temperatures. The results demonstrated that DES formed by
choline chloride (ChCl) and oxalic acid (Oxa), in a molar ratio of 1:1, using UAE showed
greater extraction efficiency. The limits of detection (LOD) and quantification obtained
were 0,2 µg g-1 and 0,5 µg g-1
, respectively. The method's accuracy was evaluated
through the analysis of certified samples, ranging from 104 to 106% recovery values,
and by comparing the results with those obtained after acid digestion, with no
significant difference (t-test, at 95% of confidence level). The concentrations obtained
for the wells were 1,64 – 168,39 µg g-1
(offshore) and 1,14 – 2,98 µg g-1
(onshore). The
method was applied to determine Pb in DC samples from drilling wells at different
depths, the obtained Pb concentrations ranging from 1,48 to 11,03 and 131,67 to
168,39 µg g-1
for samples from onshore and offshore wells, respectively. In relation to
principles of green chemistry, the method scored 0,56, which was higher than the
conventional acid digestion method in a digestion block (0,38), meeting several
principles of green analytical chemistry. Thus, the DES-UAE method for extracting Pb
from CP proved to be effective, simple and environmentally friendly. |
pt_BR |
dc.format.extent |
58 |
pt_BR |
dc.language.iso |
pt_BR |
pt_BR |
dc.publisher |
Florianópolis, SC. |
pt_BR |
dc.rights |
Open Access. |
en |
dc.subject |
Solvente eutético profundo |
pt_BR |
dc.subject |
Extração assistida por ultrassom |
pt_BR |
dc.subject |
Metais |
pt_BR |
dc.subject |
Análise espectrométrica |
pt_BR |
dc.subject |
Cascalhos de perfuração |
pt_BR |
dc.title |
Determinação de chumbo em cascalhos de perfuração de poços de petróleo por GF AAS após extração com solvente eutético profundo |
pt_BR |
dc.type |
TCCgrad |
pt_BR |
dc.contributor.advisor-co |
Ferreira, Bruno L. |
|