Avaliação da microdureza de resinas compostas submetidas à diferentes métodos de pós-polimerização

DSpace Repository

A- A A+

Avaliação da microdureza de resinas compostas submetidas à diferentes métodos de pós-polimerização

Show simple item record

dc.contributor Universidade Federal de Santa Catarina. pt_BR
dc.contributor.advisor Silva, Silvana Batalha
dc.contributor.author Casteler, Paola Luiz
dc.date.accessioned 2023-12-14T02:14:09Z
dc.date.available 2023-12-14T02:14:09Z
dc.date.issued 2023-11-06
dc.identifier.uri https://repositorio.ufsc.br/handle/123456789/253157
dc.description TCC (graduação) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Odontologia. pt_BR
dc.description.abstract A técnica semidireta é recomendada na reabilitação de dentes posteriores com cavidades extensas, porém, ainda não existem estudos suficientes sobre a necessidade de se realizar procedimentos de pós-polimerização, ou mesmo, um protocolo definido que aprimore as suas propriedades mecânicas. Sendo assim, o objetivo deste trabalho foi comparar a influência de diferentes métodos de pós polimerização utilizadas em restaurações semi-diretas, em relação à microdureza de duas resinas compostas nanohíbridas: Zinconfill e Applic. As amostras padronizadas foram confeccionadas com 1cm de diâmetro e 2,6mm de espessura, polimerizadas na base e no topo seguindo as recomendações do fabricante. Com um total de 80 amostras padronizadas, os espécimes das duas diferentes resinas compostas foram subdivididos em 4 subgrupos de acordo com o método de pós-polimerização empregado (n=10). Em seguida, os espécimes foram distribuídos aleatoriamente em 4 subgrupos: Subgrupo 1 – controle; Subgrupo 2 – fotoativação complementar por 3 segundos, no topo e na base, em alta potência (3.200 mW/cm²); Subgrupo 3 – pós polimerização adicional em forno microondas, com imersão em 200ml de água e irradiados por 4 minutos e 27 segundos; Subgrupo 4 – pós-polimerização em Autoclave a 129⁰C por 16 minutos. Após sete dias de armazenamento imersas em água e sob abrigo da luz, as amostras foram submetidas ao teste de microdureza Vickers. Os valores médios foram tabulados e submetidos a análise estatística ANOVA e teste de Bonferroni. Observou-se que o grupo Applic apresentou os valores de dureza mais elevados, com uma diferença estatisticamente significativa em relação ao grupo Zirconfill, para todos os métodos de pós-polimerização testados. Tanto a pós-polimerização em micro-ondas quanto em autoclave proporcionaram os resultados mais favoráveis para ambos os grupos. Com base nas conclusões deste estudo, fica evidente que a pós-polimerização teve um impacto positivo nos valores de microdureza, e que a composição específica de cada resina composta desempenhou um papel crucial nos resultados obtidos pt_BR
dc.description.abstract The semi-direct technique is recommended for the rehabilitation of posterior teeth with extensive cavities, however, there are still not enough studies on the need to carry out post-polymerization procedures, or even a defined protocol that improves their mechanical properties. Therefore, the objective of this work was to compare the influence of different post-polymerization methods used in semi-direct restorations, in relation to the microhardness of two nanohybrid composite resins: Zinconfill and Applic. The standardized samples were made with 1cm in diameter and 2.6mm in thickness, polymerized at the base and top following the manufacturer's recommendations. With a total of 80 standardized samples, the specimens of two different composite resins were subdivided into 4 subgroups according to the post polymerization method used (n=10). Then, the specimens were randomly distributed into 4 subgroups: Subgroup 1 – control; Subgroup 2 – complementary photoactivation for 3 seconds, at the top and bottom, at high power (3,200 mW/cm²); Subgroup 3 – additional post-polymerization in a microwave oven, with immersion in 200ml of water and irradiated for 4 minutes and 27 seconds; Subgroup 4 – post-polymerization in Autoclave at 129⁰C for 16 minutes. After seven days of storage immersed in water and protected from light, the samples were applied to the Vickers microhardness test. The average values were tabulated and subjected to ANOVA and Bonferroni test statistical analysis. Note that the Applic group presented the highest hardness values, with a statistically significant difference in relation to the Zirconfill group, for all post polymerization methods tested. Both microwave and autoclave post-polymerization provided the more detailed results for both groups. Based on the conclusions of this study, it is clear that post-polymerization had a positive impact on microhardness values, and that the specific composition of each resin played a crucial role in the results obtained. pt_BR
dc.format.extent 49 pt_BR
dc.language.iso pt_BR pt_BR
dc.publisher Florianópolis, SC. pt_BR
dc.rights Open Access. en
dc.subject Dureza pt_BR
dc.subject Resinas Compostas pt_BR
dc.subject Polimerização pt_BR
dc.title Avaliação da microdureza de resinas compostas submetidas à diferentes métodos de pós-polimerização pt_BR
dc.type TCCgrad pt_BR
dc.contributor.advisor-co Machado, Renata Gondo


Files in this item

Files Size Format View Description
Paola Luiz Casteler - BU.pdf 2.112Mb PDF View/Open TCC

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Browse

My Account

Statistics

Compartilhar