Análise da acurácia de protocolos de fotogrametria para escaneamento tridimensional de modelos odontológicos edêntulos inferiores.

DSpace Repository

A- A A+

Análise da acurácia de protocolos de fotogrametria para escaneamento tridimensional de modelos odontológicos edêntulos inferiores.

Show simple item record

dc.contributor Universidade Federal de Santa Catarina. pt_BR
dc.contributor.advisor Caldas, Ricardo Armini
dc.contributor.author Franceschetti, Karen Ribeiro
dc.date.accessioned 2024-07-06T13:10:44Z
dc.date.available 2024-07-06T13:10:44Z
dc.date.issued 2024-06-04
dc.identifier.uri https://repositorio.ufsc.br/handle/123456789/255587
dc.description TCC (graduação) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Odontologia. pt_BR
dc.description.abstract A fotogrametria representa uma promissora alternativa na odontologia, tornando-se essencial avaliar sua capacidade em gerar resultados precisos em modelos edêntulos para sua adoção e aprimoramento. Dessa forma, o objetivo foi avaliar a precisão da fotogrametria no escaneamento tridimensional de modelos odontológicos edêntulos inferiores. Utilizou-se um modelo edêntulo de manequim odontológico confeccionado em Gesso Pedra Tipo IV, que foi digitalizado por um scanner de bancada (Medit Identica Hybrid t500) para obter o modelo de referência. Para a obtenção dos modelos experimentais foram empregados dois métodos utilizando aparelho smartphone: (1) a partir de fotografias e (2) a partir de vídeos. Posteriormente, os modelos foram reconstruídos tridimensionalmente pelo software Agisoft Metashape Standard (v.1.8.2). A precisão dos modelos 3D experimentais em relação ao modelo de referência foi avaliada em 100.000 pontos distintos com auxílio do Software CloudCompare (v.2.13) pela sobreposição das nuvens de pontos. Ambos os métodos experimentais apresentaram homogeneidade diante do modelo de referência, sendo o método 1 com média das diferenças variando entre 0,017mm e 0,036 mm (DP variando de ±0,17mm a ±0,25mm) e o método 2 com média das diferenças variando entre 0,035mm e 0,075mm (DP variando de ±0,30mm a ±0,40mm). Na análise qualitativa, as regiões que apresentaram maior divergência ao modelo de referência foram o fundo de vestíbulo e assoalho lingual, enquanto a área com maior similaridade foi à crista do rebordo alveolar em ambos os modelos experimentais. Concluiu-se que a técnica de fotogrametria apresenta precisão adequada para a digitalização de modelos edêntulos, sendo uma opção viável em substituição ao scanner de bancada. pt_BR
dc.description.abstract Photogrammetry represents a promising alternative in dentistry, making it essential to evaluate its ability to generate accurate results in edentulous models for its adoption and improvement. Therefore, the objective was to evaluate the accuracy of photogrammetry in three-dimensional scanning of lower edentulous models. An edentulous dental mannequin model made of Type IV Stone Plaster was used, which was scanned by a bench scanner (Medit Identica Hybrid t500) to obtain the reference model. To obtain the experimental models, two different methods were used using a smartphone device: (1) from photographs and (2) from videos. Subsequently, the models were three-dimensionally reconstructed using the Agisoft Metashape Standard software (v.1.8.2). The accuracy of the experimental 3D models in relation to the reference model was evaluated on 100,000 distinct points using CloudCompare Software (v.2.13) by superimposing the point clouds. The experimental models (1) were homogeneous compared to the reference model, with mean differences varying between 0.017mm and 0.036mm (SD ranging from ±0.17mm to ±0.25mm). The experimental models (2) also presented homogeneity compared to the reference model, with mean differences varying between 0.035mm and 0.075mm (SD ranging from ±0.30mm to ±0.40mm). The models using the photography method showed greater uniformity when compared to the video model. In the qualitative analysis, the regions that showed the greatest divergence from the reference model were the bottom of the vestibule and lingual floor, while the area with the greatest similarity was the crest of the alveolar ridge in both experimental models. It was concluded that the photogrammetry technique presents adequate precision for the digitization of edentulous models, being a viable option to replace the bench scanner. pt_BR
dc.format.extent 38 pt_BR
dc.language.iso por pt_BR
dc.publisher Florianópolis, SC. pt_BR
dc.rights Open Access. en
dc.subject Fotogrametria pt_BR
dc.subject Técnica de Moldagem Odontológica pt_BR
dc.subject Modelos Dentários pt_BR
dc.subject Informática Odontológica pt_BR
dc.subject Arcada Edêntula pt_BR
dc.subject Prótese Dentária pt_BR
dc.title Análise da acurácia de protocolos de fotogrametria para escaneamento tridimensional de modelos odontológicos edêntulos inferiores. pt_BR
dc.type TCCgrad pt_BR
dc.contributor.advisor-co Zatt, Fernanda Pretto


Files in this item

Files Size Format View Description
Embargo_TCC_Karen_assinado-1.pdf 457.1Kb PDF View/Open Embargo
TCC_KAREN_VERSÃO_FINALIZADA.pdf 3.263Mb PDF View/Open

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Browse

My Account

Statistics

Compartilhar