Avaliação de Desempenho de Painéis em Taipa de Mão: Edificações Experimentais de Habitação 001 e 002 em São Carlos - SP
Show simple item record
dc.contributor.author |
Inafuku, Hector Yudi Yokoyama |
|
dc.contributor.author |
Ino, Akemi |
|
dc.date.accessioned |
2024-08-06T15:26:02Z |
|
dc.date.available |
2024-08-06T15:26:02Z |
|
dc.date.issued |
2024-08-07 |
|
dc.identifier.issn |
2596-237X |
|
dc.identifier.uri |
https://repositorio.ufsc.br/handle/123456789/256876 |
|
dc.description |
presente pesquisa, propõe avaliar o desempenho dos painéis com enfoque na durabilidade, a partir da definição e verificação do atendimento de requisitos e critérios de desempenho, considerando características de detalhes projetuais e de implantação. |
pt_BR |
dc.description.abstract |
Entre os anos de 1998 e 1999, duas unidades experimentais de habitação foram construídas na USP São
Carlos (SP), com o intuito de pesquisar o uso de tecnologias de baixo carbono em projetos de habitação
social. Em ambas as unidades, foram projetados e executados painéis modulares pré-fabricados em taipa
de mão como um de seus subsistemas de vedação experimentados, tendo base modular de 75cm e altura
de 2,40m, com estrutura de pinusserrado. A presente pesquisa, propõe avaliar o desempenho dos painéis
com enfoque na durabilidade, a partir da definição e verificação do atendimento de requisitos e critérios
de desempenho, considerando características de detalhes projetuais e de implantação. Esta verificação é
realizada com a identificação visual das manifestações patológicas, como fissuras, manchas e
destacamentos sob a superfície dos painéis, por fotografias da fachada via voo de drone. |
pt_BR |
dc.description.abstract |
Between 1998 and 1999, two experimental housing units were built at USP São Carlos (SP) with the
aim of researching the use of low-carbon technologies in social housing projects. In both units,
prefabricated modular panels were designed and executed in wattle and daub, with a modular base of
75 cm and a height of 2.40 m, using sawn pine as one of their experimental sealing subsystems. This
research proposes to evaluate the performance of the panels with a focus on durability, by defining and
verifying the fulfillment of performance requirements and criteria, considering design and
implementation detail characteristics. This verification is established through the visual identification
of pathological manifestations, such as cracks, stains, and detachment on the surface of the panels,
using photographs of the facade taken by drone flights |
pt_BR |
dc.language.iso |
por |
pt_BR |
dc.publisher |
Virtuhab |
pt_BR |
dc.subject |
Taipa de mão |
pt_BR |
dc.subject |
Construção com terra |
pt_BR |
dc.subject |
Avaliação de Durabilidade |
pt_BR |
dc.title |
Avaliação de Desempenho de Painéis em Taipa de Mão: Edificações Experimentais de Habitação 001 e 002 em São Carlos - SP |
pt_BR |
dc.type |
Article |
pt_BR |
Files in this item
This item appears in the following Collection(s)
Show simple item record
Search DSpace
Browse
-
All of DSpace
-
This Collection
My Account
Statistics
Compartilhar