Avaliação quantitativa de risco microbiológico: estudo de caso aplicado ao uso de efluentes tratados como água de reúso para fins urbanos em Santa Catarina
Show simple item record
dc.contributor |
Universidade Federal de Santa Catarina. |
pt_BR |
dc.contributor.advisor |
Magri, Maria Elisa |
|
dc.contributor.author |
Fangier, Alexandre |
|
dc.date.accessioned |
2024-12-19T14:46:49Z |
|
dc.date.available |
2024-12-19T14:46:49Z |
|
dc.date.issued |
2024-12-12 |
|
dc.identifier.uri |
https://repositorio.ufsc.br/handle/123456789/262276 |
|
dc.description |
TCC (graduação) - Universidade Federal de Santa Catarina, Centro Tecnológico, Engenharia Sanitária e Ambiental. |
pt_BR |
dc.description.abstract |
O estudo avaliou os riscos microbiológicos associados ao reúso de efluentes tratados de uma
Estação de Tratamento de Esgoto localizada em Florianópolis, SC, considerando diferentes
cenários de uso em atividades urbanas. O objetivo foi estimar o risco anual de infecção por
Escherichia coli patogênica, utilizando a metodologia de Avaliação Quantitativa de Risco
Microbiológico (AQRM), com base em dados históricos da estação. Para isso, foram analisadas
as concentrações de E. coli no efluente tratado, empregando-se modelagens matemáticas e a
Simulação de Monte Carlo para estimar as probabilidades de infecção em diferentes cenários
de exposição. A eficiência da ETE na remoção de E. coli apresentou mediana de 4,15 unidades
log10, dentro do intervalo esperado para o sistema de tratamento utilizado (UASB + lodos
ativados com decantador secundário + desinfecção). Atividades como irrigação de jardins,
lavagem de veículos e pisos apresentaram riscos anuais de infecção inferiores ao limite de 0,1%
estabelecido pela Organização Mundial da Saúde (OMS), enquanto o uso de efluentes tratados
em descargas sanitárias e irrigação de áreas públicas ultrapassou esse limite, com riscos de
0,195% e 0,116%, respectivamente. A frequência de exposição destacou-se como um dos
principais fatores para o aumento do risco em determinados cenários, mesmo quando os
volumes ingeridos ou inalados eram baixos. O estudo conclui que o reúso de efluentes tratados
é viável e apresenta riscos aceitáveis para a maioria das atividades avaliadas, desde que sejam
aplicadas medidas de mitigação em cenários mais críticos, como no uso em descargas sanitárias
e irrigação de áreas públicas. |
pt_BR |
dc.description.abstract |
The study evaluated the microbiological risks associated with the reuse of treated effluents from
a Wastewater Treatment Plant located in Florianópolis, SC, considering different usage
scenarios in urban activities. The objective was to estimate the annual infection risk by
pathogenic Escherichia coli, using the Quantitative Microbial Risk Assessment (QMRA)
methodology, based on historical data from the plant. To this end, E. coli concentrations in the
treated effluent were analyzed, employing mathematical modeling and Monte Carlo Simulation
to estimate infection probabilities across different exposure scenarios. The treatment plant's
efficiency in removing E. coli showed a median of 4.15 log10 units, within the expected range
for the treatment system used (UASB + activated sludge with secondary sedimentation +
chlorination disinfection). Activities such as garden irrigation, vehicle washing, and floor
cleaning presented annual infection risks below the 0.1% limit established by the World Health
Organization (WHO), while the use of treated effluents in toilet flushing and public area
irrigation exceeded this threshold, with risks of 0.195% and 0.116%, respectively. Exposure
frequency emerged as one of the main factors increasing risk in certain scenarios, even when
ingested or inhaled volumes were low. The study concludes that the reuse of treated effluents
is viable and poses acceptable risks for most evaluated activities, if mitigation measures are
applied in more critical scenarios, such as in toilet flushing and public area irrigation. |
pt_BR |
dc.format.extent |
64 f. |
pt_BR |
dc.language.iso |
por |
pt_BR |
dc.publisher |
Florianópolis, SC. |
pt_BR |
dc.rights |
Open Access. |
en |
dc.subject |
Avaliação de risco |
pt_BR |
dc.subject |
Escherichia coli |
pt_BR |
dc.subject |
AQRM |
pt_BR |
dc.subject |
Água de reúso |
pt_BR |
dc.subject |
Reuse water |
pt_BR |
dc.title |
Avaliação quantitativa de risco microbiológico: estudo de caso aplicado ao uso de efluentes tratados como água de reúso para fins urbanos em Santa Catarina |
pt_BR |
dc.type |
TCCgrad |
pt_BR |
Files in this item
This item appears in the following Collection(s)
Show simple item record
Search DSpace
Browse
-
All of DSpace
-
This Collection
My Account
Statistics
Compartilhar