Falhas mecânicas em próteses sobre implantes
Show simple item record
dc.contributor |
Universidade Federal de Santa Catarina |
pt_BR |
dc.contributor.advisor |
Cardoso, Antonio Carlos |
|
dc.contributor.author |
Serraglio, Bento Luiz |
|
dc.date.accessioned |
2025-05-12T13:36:47Z |
|
dc.date.available |
2025-05-12T13:36:47Z |
|
dc.date.issued |
2005 |
|
dc.identifier.uri |
https://repositorio.ufsc.br/handle/123456789/265007 |
|
dc.description |
Monografia de Especialização - Universidade Federal de Santa Catarina. Centro de Ciências da Saúde. Curso de Especialização em Implantodontia |
pt_BR |
dc.description.abstract |
Falhas precoces de implantes estão associadas à técnica cirúrgica inadequada e a pobre
quantidade óssea no sítio cirúrgico. Quanto Às causas da perda tardia, entre outras podemos citar
desadaptação das próteses, problemas relacionados À oclusão,cargas não axiais, hábitos
parafuncionais, sobrecargas por cantilevers. Consenso tem sido manifestado que a perda de osso
marginal ao redor dos implantes pode estar associada com sobrecarga oclusal. As causas de
afrouxamento dos parafusos, das próteses e fratura dos componentes são multifatoriais. A
longevidade na integridade da unido do parafuso do implante com o intermediário e do
intermediário com a estrutura da prótese é essencial para o sucesso da prótese. A distribuição
biomecânica da força em próteses suportadas por implantes é diferente da força sobre dentes
naturais, em função do ligamento periodontal, que permite micromovimentos. Em razão do
implante não apresentar micromovimentos há a necessidade de relacionamento cúspide-fossa,
diminuição da inclinação da Área de impacto oclusal e redução da superfície oclusal. |
pt_BR |
dc.description.abstract |
Premature failures of the implants are associated with inadequate surgical technique and
with the poor quantity of bones at the surgical site. About the causes of late loss, among other
problems related to the occlusion, non-axial load, parafunctional habits, overloads by cantilevers.
An agreement has been manifested that the loss of marginal bone around the implants might be
associated with the occlusal overload. The causes of slackening of screws, the slackening of
prostheses and the fracture of components are multifactorial. The longevity at the integrity of the
union of the screw of the implant with the abutment, and the longevity of the abutment with the
structure of the prostheses are essential to the success of the prostheses. The biomechanical
distribution of the force in implant prostheses is different of the force along natural teeth, due to
the periodontal ligament, which allows micromovements. Due to the fact that the implant does
not show micromovements there is the necessity of the relation centering the occlusal contact,
reduction of the inclination of the occlusal impact area and reduction of the occlusal table. |
pt_BR |
dc.format.extent |
38 f. |
pt_BR |
dc.language.iso |
por |
pt_BR |
dc.publisher |
Florianópolis, SC |
pt_BR |
dc.subject |
Implantes dentários |
pt_BR |
dc.subject |
Prótese sobre implantes osseointegrados |
pt_BR |
dc.title |
Falhas mecânicas em próteses sobre implantes |
pt_BR |
dc.type |
TCCes |
pt_BR |
Files in this item
This item appears in the following Collection(s)
Show simple item record
Search DSpace
Browse
-
All of DSpace
-
This Collection
My Account
Statistics
Compartilhar