Quantificação da densidade óptica ideal em um filme radiográfico, no diagnóstico da cárie
Show simple item record
dc.contributor |
Universidade Federal de Santa Catarina |
pt_BR |
dc.contributor.advisor |
Costa, Edemir |
|
dc.contributor.author |
Trentin, Cleber Sarmento |
|
dc.date.accessioned |
2025-05-26T17:47:24Z |
|
dc.date.available |
2025-05-26T17:47:24Z |
|
dc.date.issued |
2002 |
|
dc.identifier.uri |
https://repositorio.ufsc.br/handle/123456789/265294 |
|
dc.description |
Monografia de Especialização - Universidade Federal de Santa Catarina. Centro de Ciências da Saúde. Curso de Especialização em Radiologia |
pt_BR |
dc.description.abstract |
Apesar dos constantes estudos realizados para o aprimoramento da imagem digital, o
fator custo tem sido decisivo, ainda nos dias atuais, para que os fabricantes de filmes
radiográficos intra e extrabucais continuem a aperfeiçoá-lo.
Assim sendo, recentemente a Kodak lançou no mercado um novo filme radiográfico
intrabucal denominado Insight, que segundo seu fabricante oferece uma imagem tão boa
quanto a do seu antecessor, denominado Ektaspeed Plus, mas com um menor tempo de
exposição dos pacientes aos raios X.
Por este motivo decidiu-se realizar o presente estudo a fim de avaliar o
comportamento destes filmes radiográficos na obtenção da imagem ideal para o diagnóstico
de cárie. Utilizando-se um aparelho de raios X da marca Dabi Atlante de 70 kVp e 8 mA, os
filmes em estudo foram expostos nos tempos de 0,4; 0,5; 0,6; 0,7; 0,8 e 1,0 segundos e
processados manualmente em solução química Kodak GBK, de acordo com a orientação do
fabricante. As radiografias foram obtidas em um modelo Phanton, constituído de uma
mandíbula humana na qual foram implantados molares e pré-molares que apresentavam
pequenas lesões de cáries proximais e de uma estrutura de resina acrílica simulando a língua e os tecidos moles.
Inicialmente, estas radiografias foram avaliadas pelo método subjetivo (análise
visual), por três professores especialistas em radiologia odontológica e por dez alunos do
curso de especialização em radiologia.
Posteriormente, somente as radiografias consideradas com densidade aceitável para
a visualização das cáries proximais foram submetidas à avaliação objetiva (análise
foto densitométrica), com a finalidade de se estabelecer a faixa de valores quantitativos do
esmalte e da dentina das imagens consideradas ideais. |
pt_BR |
dc.description.abstract |
Even though there are frequent studies to improve the digital image, nowadays still the
cost has been decisive so that the manufacturer of the intraoral and extraoral radiografhic
films continue to improve them.
That is how Kodak recently teleased in the market a new intra-oral radiographic film
callsed Insight, that according to it's manufacturer, allows you to have and image as good as
their former release the Ektaspeed Plus, but for the acquisition of this image a minor time of
patient's exposure is necessary.
Making use of na x-ray machine of the brand Dabi Atlante of 70 Kvp and 8 mA, the
films were exposed in a sequence of 0,4; 0,5; 0.6; 0,7; 0,8; 1,0s and were submited in a series
of operation in manufactures in a Kodak GBX solution, following the manufacturer's
orientation.
The radiographs were acquirred in a Phantom model composed of a human jaw where
molae teeth and pre-molares that had small proximal cavities, an acrylic resin structure
simulation tongue and soft tissues.
Initially these radiographs were evaluates through the subjetive method (visual
analysis), accomplish by theree teachers experts in dentistry radiology and students of the
radiology specialization course.
Subsequently only the radiographs considered with acceptable density for a
visualization of the proximal cavities were submited to an objetive evaluation
(photodensitometric analysis) with the goal to stablish the zone of the quantitative values of
the enamel and the dentin, of the images considered ideal. |
pt_BR |
dc.format.extent |
66 f. | il. |
pt_BR |
dc.language.iso |
por |
pt_BR |
dc.publisher |
Florianópolis, SC |
pt_BR |
dc.subject |
Dentes |
pt_BR |
dc.subject |
Radiologia |
pt_BR |
dc.subject |
Medidas oticas |
pt_BR |
dc.subject |
densitometria |
pt_BR |
dc.subject |
filmes radiográficos |
pt_BR |
dc.title |
Quantificação da densidade óptica ideal em um filme radiográfico, no diagnóstico da cárie |
pt_BR |
dc.type |
TCCes |
pt_BR |
Files in this item
This item appears in the following Collection(s)
Show simple item record
Search DSpace
Browse
-
All of DSpace
-
This Collection
My Account
Statistics
Compartilhar