dc.contributor |
Universidade Federal de Santa Catarina |
pt_BR |
dc.contributor.advisor |
Lopes, Guilherme Carpena |
pt_BR |
dc.contributor.author |
Chraim, Gustavo Georges de Mattos |
pt_BR |
dc.date.accessioned |
2016-09-20T04:26:14Z |
|
dc.date.available |
2016-09-20T04:26:14Z |
|
dc.date.issued |
2016 |
pt_BR |
dc.identifier.other |
341092 |
pt_BR |
dc.identifier.uri |
https://repositorio.ufsc.br/xmlui/handle/123456789/167845 |
|
dc.description |
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2016. |
pt_BR |
dc.description.abstract |
Este estudo avaliou o grau de conversão (DC) pela técnica FTIR-ATR e a nanodureza pela técnica de Oliver e Phar de um cimento resinoso de cura dual (RelyX Ultimate, 3M ESPE) fotoativado através de diferentes espessuras da resina nanocerâmica (NCR) LAVA Ultimate (3M ESPE) (0mm, 1mm, 2mm e 5mm), com diferentes tempos de fotoativação (20s e 40s) à uma irradiação constante de 1100mW/cm², imediatamente após a fotoativação e após 24 horas. Os dados coletados foram analisados por uma análise de variância de 3 fatores para medidas repetidas e os efeitos das interações foram analisados pelo teste de Sidak. Para o DC, os resultados mostraram que todos os fatores influenciam significativamente (p<0,001), sendo os maiores graus de conversão são obtidos após 24 horas (p<0,001), com a menor espessura de NCR (p<0,001) e fotoativação por 40s (p<0,001). Também ficou constatada a interação dupla entre todos estes fatores (p<0,001), mas o resultado da interação tripla foi não significativo (p=0,104). Quanto à nanodureza, todos os fatores estudados influenciaram a nanodureza (p<0,001), assim como a interação dupla entre eles (p<0,001) e a interação tripla entre os fatores (p<0,001).<br> |
pt_BR |
dc.description.abstract |
Abstract : This study evaluated the degree of conversion (DC) by FTIR-ATR technique and nanohardness by Oliver and Phar technique of a dual cured resin cement (RelyX Ultimate, 3M ESPE) photoactivated through different thicknesses of nanoceramic resin (NCR) LAVA Ultimate (3M ESPE) (0 mm, 1 mm, 2 mm and 5 mm) with different curing times (20s and 40s) at a constant irradiation 1100mW / cm², immediately after curing and after 24 hours. The collected data was analyzed by 3-way ANOVA repeated measures and the effects of the interactions were analyzed by Sidak test. DC results were significant to all factors (p <0.001), and the highest degrees of conversion are obtained after 24 hours (p <0.001), low thickness NCR (p <0.001) and 40 seconds light cure (p <0.001). It was also found double interaction between all of these factors (p <0.001), but the result of the triple interaction was not significant (p = 0.104). Nanohardness was influenced by all these factors (p <0.001), as well as double interaction between them (p <0.001) and triple interaction between factors (p <0.001). |
en |
dc.format.extent |
77 p.| il., tabs. |
pt_BR |
dc.language.iso |
por |
pt_BR |
dc.subject.classification |
Odontologia |
pt_BR |
dc.subject.classification |
Cimentos dentários |
pt_BR |
dc.subject.classification |
Resinas dentárias |
pt_BR |
dc.title |
Grau de conversão e nanodureza de um cimento resinoso dual fotoativado através de diferentes espessuras de uma resina nanocerâmica CAD/CAM |
pt_BR |
dc.type |
Tese (Doutorado) |
pt_BR |
dc.contributor.advisor-co |
Araújo, Élito |
pt_BR |