Potencialidades do aproveitamento de esgoto tratado em estações de tratamento para combate a incêndio em Florianópolis/SC

DSpace Repository

A- A A+

Potencialidades do aproveitamento de esgoto tratado em estações de tratamento para combate a incêndio em Florianópolis/SC

Show simple item record

dc.contributor Universidade Federal de Santa Catarina pt_BR
dc.contributor.advisor Sezerino, Pablo Heleno
dc.contributor.author Marimon, Marcela Samadian de Castro
dc.date.accessioned 2022-07-30T21:42:56Z
dc.date.available 2022-07-30T21:42:56Z
dc.date.issued 2022-07-26
dc.identifier.uri https://repositorio.ufsc.br/handle/123456789/237430
dc.description TCC(graduação) - Universidade Federal de Santa Catarina. Centro Tecnológico. Engenharia Sanitária e Ambiental. pt_BR
dc.description.abstract O presente estudo de caso buscou analisar o potencial envolvido no uso de esgoto tratado nas estações de Florianópolis/SC para combate a incêndio. O estudo abrangeu a definição da demanda de água dos quarteis, a verificação do atendimento a legislações da qualidade do efluente tratado, a probabilidade do contado direto desta água com vítimas nos incêndios e duas propostas de implementação do sistema, incluindo suas dificuldades e benefícios. A coleta de dados do Corpo de Bombeiros Militar de Santa Catarina foi feita através da análise de registros no sistema interno do CBMSC de 2018 a 2021 e entrevistas, estas do tipo informal realizadas com 15 bombeiros militares de plantão nos quarteis do município. Os dados das vazões das estações em 2021 e dos parâmetros de saída do tratamento das estações de 2020 e 2021 foram fornecidos pela Companhia Catarinense de Água e Saneamento, e comparados com a resolução conjunta SES/SIMA n°01 do estado de São Paulo que define a qualidade do efluente tratado para fins urbanos. A demanda de água encontrada para os seis quarteis militares de Florianópolis varia de 5.583 a 16.121 L por semana, correspondendo a menos de 1% da menor vazão gerada pelas estações. O atendimento a SES/SIMA n°01 analisou 7 dos 14 parâmetros solicitados, das seis estações. A estação da Lagoa da Conceição obteve o maior número de parâmetros dentro do solicitado (quatro), as demais estações obtiveram de três a uma análise positivas. De todas as ocorrências de incêndio registradas nos últimos quatro anos, apenas 3% tiveram vítimas atendidas, já as ocorrências que ocorrem em locais com alta taxa de circulação de pessoas representam 38% dos registros. As propostas de implementação do sistema incluem o abastecimento de cada quartel na estação de esgoto mais próxima ou o fornecimento do efluente pela estação da Lagoa da Conceição, a qual necessita de atualização de menos parâmetros de saída. Com esta pesquisa infere-se que a implantação de um sistema de reuso de efluente tratado para combate a incêndio em Florianópolis necessita da atualização e refinamento do tratamento para atendimento a legislação, mas atende a demanda de água dos quarteis e apresenta baixa probabilidade de contato de vítimas com o efluente. pt_BR
dc.description.abstract This case study’s focus was to analyse the potential in the use of treated sewage water in the firefighting stations in Florianópolis. The study covered the definition of the water demands in the headquarters, verifying the compliance with local laws and regulations regarding the treated effluent's quality, the probability of the victim's direct contact with this water, two proposals for the implementation of the system and its difficulties and benefits. Data collection from the Santa Catarina’s Military Fire Department was done by analysing the records in the CBMSC’s internal system from to 2018 to 2021, and also trough informal interviews with 15 military firefighters on duty in the city’s headquarters. The information regarding the station’s outflows in 2021 and the treatments output parameters of 2020 and 2021 were provided by Compania Catarinense de Água e Saneamento, and compared with the resolution SES/SIMA number 1 São Paulo’s state, that defines the effluent’s treatment for urban processes. The amount of water demands in six military headquarters in Florianópolis varies from 5,583 to 16,121 litres per week, corresponding in less than 1 percent of the lowest flow generated by the stations. SES/SIMA number 1 considered 7 of the 14 demanded parameters, in all six stations. Lagoa da Conceição’s station registered the highest number of parameters (four), the remaining stations registered from 1 to 3 positive results. From all fire occurrences registered in the last four years, only 3% had attended victims, whereas the ones that occur in places with high amount of people passing by represents 38% of them. The system’s implementation proposal includes supplying the headquarters with the water the nearest sewage station or with the effluent from the Lagoa da Conceição’s station, which needs fewer outgoing parameters updates. With this research its concluded that implementing an effluent reuse treated water system for solving fire occurrences in Florianópolis needs improvement on the water treatment to comply with the laws and regulations, but it meets the water demands in the headquarters and it’s highly unlikely that the victims would have direct contact with the water. pt_BR
dc.format.extent 76 f. pt_BR
dc.language.iso por pt_BR
dc.publisher Florianópolis, SC. pt_BR
dc.rights Open Access
dc.subject Florianópolis pt_BR
dc.subject Reuso pt_BR
dc.subject Combate a incêndio pt_BR
dc.subject Esgoto pt_BR
dc.subject Corpo de Bombeiros Militar pt_BR
dc.title Potencialidades do aproveitamento de esgoto tratado em estações de tratamento para combate a incêndio em Florianópolis/SC pt_BR
dc.type TCCgrad pt_BR