dc.description.abstract |
Devido ao número de pesquisas com geossintéticos para obras geotécnicas, visando soluções cada
vez mais práticas, seguras e sustentáveis, pesquisou-se uma maneira alternativa de execução de
geocélula, utilizando garrafas de polietileno tereftalato (PET), com brita como material de
preenchimento. Objetivando desenvolver um sistema de baixo custo e sustentável, foi instalado o
conjunto de geocélulas em um estacionamento não pavimentado, que passou por um período de 90
dias de exposição às intempéries e ao tráfego. As células, com diâmetro de 100 mm e altura de 80
mm, passaram por ensaios de compressão axial e amostras de PET, com 110 mm de comprimento
foram ensaiadas à tração, antes e após a exposição. Notou-se que, houve uma diminuição das
resistências de tração e compressão após a exposição, entretanto, visualmente, apesar de sofrer
alguns danos mecânicos, não houve deformação aparente do conjunto, viabilizando sua aplicação. |
pt_BR |
dc.description.abstract |
Due to the number of geosynthetic surveys for geotechnical works, aiming at increasingly
practical, safe and sustainable solutions, an alternative way of geocellular execution was
investigated, using polyethylene terephthalate (PET) bottles, with gravel as fill material. Aiming to
develop a low-cost and sustainable system, the set of geocells was installed in an unpaved parking
lot, which has undergone a period of 90 days of exposure to weather and traffic.
Cells with a diameter of 100 mm and height of 80 mm underwent axial compression tests and PET
samples, 110 mm long, were tensile tested before and after exposure.
It was observed that there was a decrease in tensile and compressive strengths after exposure,
however, visually, despite some mechanical damages, there was no apparent deformation of the
assembly, making its application possible. |
pt_BR |
dc.language.iso |
por |
pt_BR |
dc.publisher |
Grupo de Pesquisa Virtuhab/ UFSC |
pt_BR |
dc.subject |
Geocélulas; |
pt_BR |
dc.subject |
Polietileno Tereftalato |
pt_BR |
dc.subject |
Sustentabilidade |
pt_BR |
dc.subject |
Geocells; Polyethylene Terephthalate; Sustainability |
pt_BR |
dc.title |
Breve estudo de geocélulas de garrafa de Polietileno Tereftalato, aplicadas para melhoria funcional do pavimento |
pt_BR |
dc.title.alternative |
Brief study of polyethylene terephthalate bottle geocells, applied for functional pavement improvement |
pt_BR |
dc.type |
Article |
pt_BR |