Estudo e Implementação de Estratégias de Controle para uma Cervejeira Comercial
Show simple item record
dc.contributor |
Universidade Federal de Santa Catarina |
pt_BR |
dc.contributor.advisor |
Neto, Alexandre Trofino |
|
dc.contributor.author |
Seerig, Daniel Manzoni |
|
dc.date.accessioned |
2019-07-15T17:55:23Z |
|
dc.date.available |
2019-07-15T17:55:23Z |
|
dc.date.issued |
2017 |
|
dc.identifier.uri |
https://repositorio.ufsc.br/handle/123456789/197600 |
|
dc.description |
TCC(graduação) - Universidade Federal de Santa Catarina. Centro Tecnológico. Engenharia de Controle e Automação. |
pt_BR |
dc.description.abstract |
O projeto ora analisado tem como objetivo estudar os potenciais ganhos em
desempenho energético provenientes de uma lógica de controle mais eficiente
aplicada à refrigeração comercial com uso de compressores VCC. Para tanto, foi
utilizado um refrigerador do tipo cervejeira como bancada de teste. De pronto,
analisou-se o comportamento do sistema quando aplicada a lógica de controle
baseline. A partir dos dados obtidos, foram desenvolvidas duas novas estratégias de
controle, a primeira utilizando os sinais oriundos do inversor e a segunda partindo das
mesmas variáveis com a adição de um sensor de temperatura no interior do
refrigerador. Ao final, foi elaborada uma comparação do desempenho da cervejeira,
observando os resultados obtidos da aplicação das três estratégias, tem-se a
descoberta do melhor sistema a ser adotado, que será estudado e apresentado no
curso desta pesquisa. |
pt_BR |
dc.description.abstract |
The main goal of this project is to study the potential gain to be obtained using
a more efficient control law to be applied in commercial refrigeration that uses VCC
compressors. In order to develop this work, a brewer type refrigerator was used as the
test bench. The system behavior was captured when the baseline control logic was
applied. From the data collect, two new control strategies were developed, the first
using only the signal from inverter and the second from the same variables with the
addition of a temperature sensor inside the refrigerator. At the end, a comparison of
the performance of the brewery was made, observing the results collect from the
application of the three strategies, the discovery of the best system to be adopted in
different situation will be presented in the course of this document. |
pt_BR |
dc.language.iso |
pt_BR |
pt_BR |
dc.publisher |
Florianópolis, SC. |
pt_BR |
dc.rights |
Open Access |
|
dc.subject |
Refrigeração comercial, compressor VCC, leis de controle. |
pt_BR |
dc.title |
Estudo e Implementação de Estratégias de Controle para uma Cervejeira Comercial |
pt_BR |
dc.type |
TCCgrad |
pt_BR |
Files in this item
This item appears in the following Collection(s)
Show simple item record
Search DSpace
Browse
-
All of DSpace
-
This Collection
My Account
Statistics
Compartilhar